Hellenbrand Water Conditioning System H-125 Series Owner's Manual page 8

H-125 series
Hide thumbs Also See for Water Conditioning System H-125 Series:
Table of Contents

Advertisement

SET
TIME HOUR
6:35
PM
SET
TIME MINUTES
6:35
PM
SET
RETURN TO ROTATING DISPLAY
WATER HARDNESS
20
SET
GR
DAYS BETWEEN REGEN
14
SET
REGEN TIME HOUR
2:00
AM
SET
REGEN TIME MINUTES
2:00
AM
SET
RETURN TO ROTATING DISPLAY
8
seT TiMe Of DaY
Step 1
Step 1 - Press SET CLOCK.
Step 2 - Current Time (hour): Set the hour of the day using  or  buttons.
AM/PM toggles after 12. Press NEXT to go to step 3.
Step 2
Step 3 - Current Time (minutes): Set the minutes of day using  or  buttons.
Press NEXT to exit Set Clock. Press REGEN to return to previous step.
Power Loss - Lithium battery on circuit board provides up to 2 years of time
clock backup during power outages. If the power is out when battery is depleted,
only time of day needs to be reset, all other values are stored in non-volatile
memory. When time of day is flashing, replace lithium coin type 2032 battery.
Step 3
Battery back-up feature will be activated after 24 hours of power.
Do not forget to reset for daylight savings time.
Figure 9
insTaller DisplaYs/seTTinGs
Step 1
Step 1 - Press NEXT and  simultaneously for 3 seconds.
Step 2
Step 2 - Hardness: Set the amount of total compensated hardness in
grains (hardness as calcium carbonate) per gallon using  or  but-
tons. The factory setting is 20 with value ranges from 1 to 150 in 1 grain
increments. Note: The grains per gallon should be increased if soluble
iron needs to be reduced.
present. If this display shows nA -, then system is set-up in "filter" mode or
"AUTO" is not selected in softener system setup. (See page 34). Press
Step 3
NEXT to go to Step 3. Press REGEN to exit Installer Displays/Settings.
Step 3 - Day Override: This sets the number of days between regenera-
tions. If value set to "oFF" regeneration initiation is based solely on gallons
used. If value is set as a number (allowable range from 1 to 28) a regen-
eration initiation will be called for on that day even if sufficient number of
gallons were not used to call for a regeneration. Set Day Override using 
or  buttons: Factory setting is 14 days.
Step 4
• number of days between regeneration (1 to 28); or
• "oFF"
See figure 12a & b, page 11-12, for more detail on softener setup. Press
NEXT to go to step 4. Press REGEN to return to previous step.
Step 4 - Regeneration Time (hour): Set the hour of day for regeneration
Step 5
using  or  buttons. AM/PM toggles after 12. The factory setting time is
2:00 a.m. This display will show "REGEN" "IMMEDIATE ON zERO GAL" if
"Immediate" is selected on Step 12 of softener set-up. See page 34. Press
NEXT to go to step 5. Press REGEN to return to previous step.
Step 5 - Regeneration Time (minutes): Set the minutes of day for regen-
eration using  or  buttons. This display will not be shown if system is set
for immediate regeneration. Press NEXT to exit Installer Displays/Settings.
Press REGEN to return to previous step.
Figure 10a
=  Up Arrow
=  Down Arrow
=  Up Arrow
=  Down Arrow
Add 3 grains of hardness for each ppm of iron