AUXILIARY INPUT
OFF
REG
SET
BACKWASH
CYCLE1
SET
REGENERANT DRAW DN
Step 10CS
CYCLE2
SET
RINSE
Step 11CS
CYCLE 3
SET
FILL
Step 12CS
CYCLE 4
SET
END
Step 13CS
CYCLE 5
SET
RETURN TO ROTATING DISPLAY
17
STEP 8CS – If Twin Alternating capability is selected, auxilliary input option is not available. This
Step 8CS
display will be available to select the use of an outside signal to control the initiation of a regenera-
tion. Selection only matters if a connection is made to the two pin connector labeled DP SWITCH
located on the printed circuit board. Following is an explanation of the options:
• ON 0 REG – If the dP switch is closed for an accumulative time of 2 minutes, a regeneration will
occur immediately.
• DELAY REG – If the dP switch is closed for an accumulative time of 2 minutes, a regeneration will
occur at the schedule regeneration time.
• HOLD REG – If the dP switch is closed a regeneration will be prevented from occurring.
• OFF
Press NEXT to go to Step 9CS. Press REGEN to return to previous step.
Step 9CS
STEP 9CS – Press the  or  buttons until selection of first cycle appears in left upper corner, in
this example BACKWASH is selected. Press NEXT to go to Step 10CS. Press REGEN to return to
previous step.
STEP 10CS – Press the  or  buttons until selection of second cycle appears in left upper
corner, in this example Regenerant Draw DN is selected. For a PM6 control valve prior to select-
ing DN or UP or not selecting a regenerant flow cycle, verify the correct valve body, main piston,
regenerant piston and stack are being used and the injector or injector plug(s) are in the correct
location. Press NEXT to go to Step 11CS. Press REGEN to return to previous step.
STEP 11CS – Press the  or  buttons until selection of third cycle appears in left upper corner,
in this example RINSE is selected. Press NEXT to go to Step 12CS. Press REGEN to return to
previous step.
STEP 12CS – Press the  or  buttons until selection of fourth cycle appears in left upper corner,
in this example FILL is selected. Press NEXT to go to Step 13CS. Press REGEN to return to
previous step.
STEP 13CS – Press the  or  buttons until last regeneration cycle; END appears. (Up to 9
regeneration modes are possible). END MUST BE SELECTED AS LAST CYCLE.