Hellenbrand Water Conditioning System H-125 Series Owner's Manual page 13

H-125 series
Hide thumbs Also See for Water Conditioning System H-125 Series:
Table of Contents

Advertisement

DAYS SINCE REGEN
2
DAY
SINCE LAST REGEN
342
GAL
RESERVE HISTORY
0 160
DAY
GAL
USAGE HISTORY
108
1
DAY
GAL
MAX FLOW
6
12.7
DAY
GAL
RETURN TO NORMAL MODE
13
=  Up Arrow
Reset Diagnostic Values: Hold
UP/DOWN buttons for 3 seconds.
STEP 1D – Press
Step 1D
does not appear in 5 seconds the lock on the valve is activated.
STEP 2D – Days, since last regeneration: This display shows the days since
Step 2D
the last regeneration occurred. Press the NEXT button to go to Step 3D. Press
REGEN to exit Diagnostics.
STEP 3D – Volume, since last regeneration: This display shows gallons of water
Step 3D
that has been treated since the last regeneration. This display will equal zero if a
water meter is not installed. Press the NEXT button to go to Step 4D. Press RE-
GEN to return to previous step.
Step 4D
STEP 4D – Volume of reserve capacity used for last 7 days: If the unit is set up
as a softener, a meter is installed and Set Volume Capacity is set to "Auto", this dis-
play shows 0 day (for today) and the reserve capacity. Pressing the
show day 1 (which would be yesterday) and displays the reserve capacity. Press-
ing the
button again will show day 2 (the day before yesterday) and the reserve
capacity. Keep pressing the
The
button can be pressed to move backwards in the day series. Press NEXT
button at any time to go to Step 5D. Press REGEN to return to previous step.
STEP 5D – Volume of water used, 63-day usage history: This display shows day
0 (for today) and 1 (for yesterday) will show day 2 (which would be the day before
yesterday) and flashes the volume of water treated on that day. Continue to press
Step 5D
the
button to show the volume of water treated for the last 63 days. If a regen-
eration occurred on the day the "letter R" will also be displayed. This display will
show dashes if a water meter is not installed. Press the NEXT button at any time
to go to Step 6 D. Press REGEN to return to the previous step.
STEP 6D – Flow rate, maximum of each of last seven days: The maximum flow
rate in gallons per minute that occurred in each of the last seven days will be
displayed. Press
This display will equal zero if a water meter is not installed. Press the NEXT button
to exit Diagnostics. Press REGEN to return to the previous step.
Step 6D
To reset diagnostic data push "Next" and
then press "
DiaGnOsTiCs
=  Down Arrow
NEXT/DOWN buttons for 3 seconds, then hold
or
simultaneously for three seconds. If screen in step 2D
button to show the capacity for days 3, 4, 5 and 6.
arrow to display maximum flow rate today = 0, yesterday = 1.
&
" button simultaneously for 3 seconds.
button until TYPE appears in window,
button will