Hellenbrand Water Conditioning System H-125 Series Owner's Manual page 10

H-125 series
Hide thumbs Also See for Water Conditioning System H-125 Series:
Table of Contents

Advertisement

SOFTENING TIME
120:00
SET
MIN
BACKWASH TIME
8:00
SET
MIN
DRAW TIME
60:00
SET
MIN
BACKWASH TIME
8:00
SET
MIN
RINSE TIME
4:00
SET
MIN
GRAIN OF CAPACITY
64.0
SET
x1K
NORMAL
FILL
SET
RESERVE CALCULATOR
AUTO
SET
Figure 12a
10
STEP 4 S – Select the time for the second cycle (which in this example is SOFTENING)
Step 4S
using  or  button. Press NEXT to go to Step 5S. Press REGEN to return to the previous
step.
Step 5S
STEP 5 S – Select the time for the third cycle (which in this example is BACKWASH) using
the  or  button. Press NEXT to go to Step 6S. Press REGEN to return to the previous
step.
STEP 6 S – Select the time for the fourth cycle (which in this example is dn BRINE) using
Step 6S
the  or  button. Press NEXT to go to Step 7S. Press REGEN to return to the previous
step.
STEP 7 S – Select the time for the fifth cycle (which in this example is BACKWASH) using
the  or  button. Press NEXT to go to Step 8S. Press REGEN to return to the previous
Step 7S
step.
STEP 8 S – Select the time for the sixth cycle (which in this example is RINSE) using the
Step 8S
 or  button. Press NEXT to go to Step 9S. Press REGEN to return to the previous step.
STEP 9 S - Set Grain Capacity using the  or  button. The ion exchange capacity is in
Step 9S
grains of hardness as calcium carbonate for the system based on the pounds of salt that
will be used. The allowable grains capacity range varies from 5,000 to 500,000 grains. The
increment increase is 500 for the range from 5000 to 50,000; 1000 for the range of 50,000 to
200,000; and 2000 for the range of 200,000 to 500,000. Grains capacity is affected by the fill
time. The grains capacity for the selected lbs. salting should be confirmed by testing. The
capacity and hardness levels entered are used to automatically calculate reserve capacity
when gallon capacity is set to AUTO. Factory setting is the capacity of the softener at
medium salting. See Page 33. Press NEXT to go to Step 10S. Press REGEN to return to
Step 10S
previous step.
STEP 10 S – Select between proportional or normal brining. Use  or  buttons to
select. Proportional brining is only available if configured as prefill/upflow softener or
screen will not appear. Proportional brining will divide the actual gallons used by calculated
volumetric capacity then multiply fill volume by this percentage. This option requires a func-
tioning meter. Factory Setting = Normal brining. Press NEXT to go to Step 11S. Press
REGEN to return to previous step.
Step 11S
STEP 11 S – Set Gallons Capacity using  or  button. If value is set to:
• "AUTO" gallon capacity will be automatically calculated and reserve capacity will be auto-
matically estimated;
• "oFF" regeneration will be based solely on the day override set (see Installer Display/Set-
tings Step 3, page 8 / proportional brining will not fuction if OFF selected); or
• as a number of gallons (allowable range 20 to 250,000) regeneration will be based on the
value specified.
Increment increase is 20 for the range 20 to 2000, 100 for the range of 2000 to 10,000 and
500 for the range of 10,000 to 50,000 and 2000 for range of 50,000 to 250,000.
If "oFF" or a number is used, hardness cannot be set in Installer Displays/Settings Step 2,
page 8. See page 34 for more detail. Factory Setting is AUTO. Press NEXT to go to Step
12 S. Press REGEN to return to previous step.