Prox And Iclass Programming - IBC Qscan User Manual

Table of Contents

Advertisement

Proximity and iClass General Settings
X047 c m b p s
c
card style
m
masking
b
good read beep
p
parity check (26 & 28)
s
passthru
This command sets the general settings for proximity and iClass input.
If passthru ("s") is turned on, and the output mode is set to wiegand,
then no interpretation of the prox or iClass data is done. The card data is
transmitted exactly as it is on the card.
Proximity and iClass Input, Format # 1, Part 1*
X048 bbb sss sl b bss bl x
bbb
# card bits
sss
site start bit
sl
# bits for site code
b
site is lsb
bss
id start bit
bl
# bits for id
x
id is lsb
This command is the first part of a 2 part command, for setting up an
input proximity or iClass format.
* added to firmware 5/22/13
1=wiegand
0=off
0=off
0=off
0=off
000=no site
00=none
0=off
000=no id
00=none
0=off
Qscan User's Guide
2=aba
1=on
1=on
1=on
1=on
max=250
1=site is lsb
1=id is lsb
Version 1.4