IBC Qscan User Manual page 42

Table of Contents

Advertisement

Proximity and iClass Input, Format # 2 Mask, Part 2*
X057 p3 ll3 p4 ll4 p5 ll5
p3
start position
ll3
length or constant
p4
start position
ll4
length or constant
p5
start position
ll5
length or constant
All parameters have the same usage as the prior command.
* added to firmware 5/22/13
Proximity and iClass Input, Format # 3 Mask, Part 1*
X058 p1 ll1 p2 ll2
p1
start position
ll1
length or constant
p2
start position
ll2
length or constant
p1 and p2 refer to the start position in the data to start an extraction of
data. The data is extracted for a length of ll1,ll2. If p1 or p2 is 00, then
ll1 or ll2 refers to a constant value which will be inserted into the data
value. The constant value is a 3-digit ascii decimal value of the character
to insert ("A" = 065). If both p1 and ll1 (or p2 and ll2) are 0, then that
portion of the mask is ignored. See the examples at the end of this
section.
Note this mask applies only to prox/iClass cards with a bit length defined
by prox/iClass format # 3.
* added to firmware 5/22/13
Qscan User's Guide
00=ll3 is a constant
00=ll4 is a constant
00=ll5 is a constant
00=ll1 is a constant
00=ll2 is a constant
Version 1.4