Selection of Output Style
X023 a
a
Type of Output
This command is used to program the type of "emulation" output sent by
the reader. Qscans with a "wiegand" ordering code can be reprogrammed
to output any of the above formats.
Mag Emulation Control (firmware prior to 3/29/13)
X024 c d t f b pp ss
c
cstart
d
neuron mode
t
track emulation
f
f2f
b
time between pulses
pp
pulse time * 50us
ss
data settle time *10us
"c" applies to track 2 (aba) output only. When on, a C start sentinel is sent
instead of a B start sentinel. Set "d" to 1 if your system requires data to
go up at the same time as the clock signal.
To transmit in f2f format, "f" must be set to 1.
!
!
Qscan F2F circuitry supports connection to a system with a 5V or
12V pullup.
Qscan User's Guide
1=wiegand, wieaba, alphawie
2=magstripe, aba, f2f
3=wand emulation
0=off
1=on
0=off
1=on
1=track 1
2=track 2 (aba)
0=no
1=yes
1 - 5 ms
default=1 (1ms)
1 - 5 *50us
default=02 (100us)
1 - 2 *10us
default=02 (20us)