IBC Qscan User Manual page 29

Table of Contents

Advertisement

Qscan User's Guide
Version 1.4
still include bits in the output format for the id, except the id will not come from the
barcode. It will default to 0.
If id digits ("bd") is set to 00, then all remaining digits in the barcode are used for
the id.
If issue code start ("iiii") is 0000, then no issue code is extracted from the barcode
data. You may still include bits in the output format for the issue code, except the
issue code data will not come from the barcode. It will default to 0.
If issue code digits ("id") is set to 00, then all remaining digits in the barcode are
used for the issue code.
If site code bits ("ss") is set to 00, then there will be no site bits in the output.
If id bits ("bb") is set to 00, then there will be no id bits in the output.
If issue code bits ("ii") is set to 00, then there will be no issue bits in the output.
If the lsb indicator ("x,y,z") is on for any specific field, then the output data for
that field is set up using the least significant bit first. The default for most wiegand
formats is to use msb (most significant bit first).
The number of parity bits used for left parity is set by ("lpp"). If set to 000 then
there is no left parity bit.
The number of parity bits used for right parity is set by ("rpp"). If set to 000 then
there is no right parity bit.
Parity bits are calculated using sequential bits starting at the beginning of the output
bitstream for left parity, and starting at the end for right parity. Parity is even on the
left and odd on the right, unless changed using the X026 or X027 commands.
You do not have to include all of the fields (site, id, issue) in the wiegand output data
stream. The ("h,i,j") parameters define which fields are to be output and in which
order. A 1 refers to the site code field, 2 refers to the id field, 3 refers to the issue
code field, and 0 means no field. To generate a wiegand output stream with only an
id field, the values will be 2 0 0. To generate a stream with site and id, the values will
be 1 2 0. To generate a field with id first, then site, then issue, it would be 2 1 3.
A site override can be programmed using the X018 and X022 commands. To turn site
override processing on, ("k") must be set to a 1.
Page