Mag Emulation Control (firmware after 3/29/13)
X024 c d t f b pp ss l yy
c
cstart
d
neuron mode
t
track emulation
f
f2f
b
time between pulses
pp
pulse time * 50us
ss
data settle time *10us
l
lead/trail zero bits
zz
right justify zero fill
This command is the same as the prior command except for the addition
of the l and zz parameters.
Magnetic stripe data is typically preceeded with a number of 0 bits
and appended witha number of 0 bits, for synchronization. The Qscan
default is to send 10 zero bits before and after the data stream. These 0
bits can be turned off with the ("l") parameter.
Some controllers and software systems require fixed length magnetic
stipe data. The ("zz") parameter can be set to right justify the aba data
into a data field ("zz") characters long. The data is zero filled. To turn
off this option, set ("zz") to 00.
Qscan User's Guide
0=off
1=on
0=off
1=on
1=track 1
2=track 2 (aba)
0=no
1=yes
1 - 5 ms
default=1 (1ms)
1 - 5 *50us
default=02 (100us)
1 - 2 *10us
default=02 (20us)
0=yes, 1=no
default=0
zz=# digits
00=no justify
Version 1.4