Standard / extended temperature
industrial motherboard in mini-itx form factor with intel haswell processors and hm87 / qm87 express chipset (63 pages)
Memory Module Installation ............... 46 Chapter 4 AMI BIOS Setup ..................47 Overview ....................47 Main Menu ....................48 Advanced Menu ..................48 Boot Menu ....................59 Security Menu .................... 60 Save & Exit Menu ..................61 KEMX-6000 User’s Manual...
Page 4
Content Chapter 5 Driver Installation ................. 63 Appendix A DIO (Digital I/O) Sample Code ............64 Appendix B WatchDog Timer Sample Code ............66 KEMX-6000 User’s Manual...
Figure 5 Rear Panel IO ................28 Figure 6 Expansion Interfaces ..............45 Figure 7 Align the SO-DIMM Memory Module with the onboard socket ..46 Figure 8 Press down on the SO-DIMM Memory Module to lock it in place 46 KEMX-6000 User’s Manual...
Tables Tables Table 1 KEMX-6000 Specification .............. 19 Table 2 Jumper List ..................25 Table 3 JP1 AT / ATX Mode Selection ............25 Table 4 JP2 Signal / Power Selection for COM5 ........25 Table 5 JP3 Panel Backlight Power Selection for LVDS2 ......26 Table 6 JP4 Signal / Power Selection for COM6 ........
Page 7
Table 64 Advanced Menu – Super IO Configuration –Serial Port 4 Configuration ................52 Table 65 Advanced Menu – Super IO Configuration –Serial Port 5 Configuration ................53 Table 66 Advanced Menu – Super IO Configuration –Serial Port 6 Configuration ................53 KEMX-6000 User’s Manual...
Page 8
Table 71 Advanced Menu – H/W Monitor ........... 58 Table 72 Advanced Menu – CPU Advanced Configuration ......58 Table 73 Boot Menu ................... 59 Table 74 Security Menu ................60 Table 75 Save & Exit Menu ................ 61 KEMX-6000 User’s Manual...
Use extreme caution when installing or removing components. Refer to the installation instructions in this user’s guide for precautions and procedures. If you have any questions, please contact Quanmax Post-Sales Technical Support. WARNING High voltages are present inside the chassis when the unit’s power cord is plugged into an electrical outlet.
Static electricity can harm system boards. Perform service at an ESD workstation and follow proper ESD procedure to reduce the risk of damage to components. Quanmax strongly encourages you to follow proper ESD procedure, which can include wrist straps and smocks, when servicing equipment.
Page 11
Handle components and boards with care. Don’t touch the components or contacts on a board. Hold a board by its edges or by its metal mounting bracket. Do not handle or store system boards near strong electrostatic, electromagnetic, magnetic, or radioactive fields. KEMX-6000 User’s Manual...
Remove all items from the box. If any items listed on the purchase order are missing, notify Quanmax customer service immediately. Inspect the product for damage. If there is damage, notify Quanmax customer service immediately. Refer to “Warranty Policy” for the return procedure.
Quanmax or its authorized agent; or if the failure is caused by accident, acts of God, or other causes beyond the control of Quanmax or the manufacturer. Neglect, misuse, and abuse shall include any installation, operation, or maintenance of the product other than in accordance with the user’s guide.
Quanmax. Limitation of Liability In no event shall Quanmax be liable for any defect in hardware, software, loss, or inadequacy of data of any kind, or for any direct, indirect, incidental, or consequential damages in connection with or arising out of the performance or use of any product furnished hereunder.
Page 15
Line conditioners keep a system’s AC power source voltage at a fairly constant level and, therefore, can handle brownouts. Because of this added protection, line conditioners cost more than surge protectors. However, line conditioners cannot protect against a complete loss of power. KEMX-6000 User’s Manual...
Page 16
Surge protectors should be used with all UPS systems, and the UPS system should be Underwriters Laboratories (UL) safety approved. KEMX-6000 User’s Manual...
Chapter 1 Chapter 1 Introduction Overview The KEMX-6000 is a Mini-ITX form factor industrial motherboard combining the latest ® ® 2nd generation Intel Core™ i3/i5/i7 processors with the high integration of the Intel QM67 chipset. Featured are DDR3 1066/1333 SO-DIMM up to 16GB, 24-bit LVDS, HDMI, DVI-D, VGA, 2x Gigabit Ethernet, 5x SATA, 1x PCIe x 16, mini PCIe Expansion slot, 2x USB 3.0, 8x USB 2.0, 6x COM ports with Power Selection, HD...
2x ports stack with two RJ-45 connectors 6x ports via 4x headers for internal. 1x header for 8-bits DIO supported 4-bits Input and 4-bits Output 1x wafer connector for PS/2 Keyboard/Mouse 6x COM ports supported 2x DB-9 male connectors for COM1, COM2 KEMX-6000 User’s Manual...
No.1. To move a jumper from one position to another, use needle-nose pliers or tweezers to pull the pin cap off the pins and move it to the desired position. KEMX-6000 User’s Manual...
Panel Power = +5V Pitch: 2.54mm [YIMTEX 3362*03SAGR] Table 8 JP6 Backlight Power Enable Selection for LVDS1 Jumper Setting Status Backlight Enable Voltage = +3.3V Backlight Enable Voltage = +5V Active High Active Low Pitch: 2.0mm [PINREX 222-97-03GBB1] KEMX-6000 User’s Manual...
GREEN LINE OUT PINK MIC IN [Foxconn JA33331-H11P-4F] Table 15 CN10 LAN1 & USB2.0 Port 0, 1 Connector Signal Signal MDI[0]+ +USBVCC MDI[0]- USB_A- MDI[1]+ USB_A+ MDI[1]- MDI[2]+ +USBVCC MDI[2]- USB_B- MDI[3]+ USB_B+ MDI[3]- [UDE RU1-161F9WGF (XB)] KEMX-6000 User’s Manual...
Activity Yellow LED blink Table 17 CN12 CRT DB-15 & DVI-D Connector Signal Name Signal Name Green Blue DDC_DATA HSYNC VSYNC DDC_CLK Signal Name Signal Name TX2- TX2+ DDC_CLK DDC_DATA TX1- TX1+ HTPLG TX0- TX0+ TXC+ TXC- [FAN YING G205D2C01012PHN] KEMX-6000 User’s Manual...
DCD, Data carrier detect RXD, Receive data TXD, Transmit data DTR, Data terminal ready GND, ground DSR, Data set ready RTS, Request to send CTS, Clear to send RI, Ring indicator NC, Key Pitch: 2.54mm [YIMTEX 3362*05SANGR-10] KEMX-6000 User’s Manual...
RXD, Receive data TXD, Transmit data DTR, Data terminal ready GND, ground DSR, Data set ready RTS, Request to send CTS, Clear to send RI, Ring indicator/ +12V / +5V * NC, Key Pitch: 2.54mm [YIMTEX3362*05SANGR-10] *:Selected by JP2 KEMX-6000 User’s Manual...
+5V / +12V ** +5V / +12V ** BL_EN*** Pitch: 1.25mm [Townes Enterprise 1250W-07T1-V] *:BL_ADJ can be setting from 0V to 5V in BIOS setup. **:Backlight Power can be selected by JP5. ***:BL_EN can be selected by JP6 KEMX-6000 User’s Manual...
Chapter 2 Table 48 SATA1 Serial ATA Port0 Connector Signal Name [FOXCONN LD1807V-S52U] Table 49 SATA2 Serial ATA Port1 Connector Signal Name [FOXCONN LD1807V-S52U] Table 50 SATA3 Serial ATA Port2 Connector Signal Name [FOXCONN LD1807V-S52U] KEMX-6000 User’s Manual...
Chapter 2 Table 51 SATA4 Serial ATA Port3 Connector Signal Name [FOXCONN LD1807V-S52U] Table 52 SATA5 Serial ATA Port4 Connector Signal Name [FOXCONN LD1807V-S52U] Table 53 SATA6 Serial ATA Port5 Connector Signal Name [FOXCONN LD1807V-S52U] KEMX-6000 User’s Manual...
Signal Name Signal Name +USBVCC +USBVCC USB_A- USB_B- USB_A+ USB_B+ Pitch: 2.54mm [YIMTEX 3362*05SANGR-09] Table 56 USB3 USB2.0 Port 8, 9 Pin Header Signal Name Signal Name +USBVCC +USBVCC USB_A- USB_B- USB_A+ USB_B+ Pitch: 2.54mm [YIMTEX 3362*05SANGR-09] KEMX-6000 User’s Manual...
When adding or removing expansion cards, make sure that you unplug the power supply first. Meanwhile, read the documentation for the expansion card to configure any necessary hardware or software settings for the expansion card, such as jumpers, switches or BIOS configuration. KEMX-6000 User’s Manual...
SO-DIMM. Lift it out of the socket. Make sure you store the SO-DIMM in an anti-static bag. The socket must be populated with memory modules of the same size and manufacturer. KEMX-6000 User’s Manual...
This chapter provides a description of the AMI BIOS. The BIOS setup menus and available selections may vary from those of your product. For specific information on the BIOS for your product, please contact Quanmax. NOTE: The BIOS menus and selections for your product may vary from those in this chapter.
Resume From S3 By PS/2 Keyboard Options: Disabled, Enabled Resume From S3 By PS/2 Mouse Options: Disabled, Enabled Resume By PCIE Device Options: Disabled, Enabled Resume From S3 By USB Device Options: Disabled, Enabled Resume By RTC Alarm Options: Disabled, Enabled KEMX-6000 User’s Manual...
Change User Password Select this item to set or change the user password. The User Password item on top of the screen displays the default Not Installed. After you have set a password, this item displays Installed. KEMX-6000 User’s Manual...
Load Optimal Defaults Load Optimal Default values for all the setup values. This option allows you to load optimal default values for each of the parameters on the Setup menus, which will KEMX-6000 User’s Manual...
Page 62
Load Optimal Default values for all the setup values. This option allows you to load failsafe default values for each of the parameters on the Setup menus, which will provide the most stable performance settings. The F8 key can be used for this operation. KEMX-6000 User’s Manual...
Chapter 5 Driver Installation If your KEMX-6000 does not come with an operating system pre-installed, you will need to install an operating system and the necessary drivers to operate it. After you have finished assembling your system and connected the appropriate power source, power it up using the power supply and install the desired operating system.
Page 64
Appendix A Appendix A DIO (Digital I/O) Sample Code //*************************************************************** //KEMX-6000 DOS DIO sample program //Please compile with Turbo C 3.0 to utilized the program //0:Low 1:High //DI_1: IOport 0x50C bit2 DO_1: IOport 0x539 bit4 //DI_2: IOport 0x50C bit3 DO_2: IOport 0x539 bit5...
Page 65
//DO_3 is bit 6 outp(0x539,RetVal); RetVal=inp(0x53B);//IO Port: 0x53B RetVal=(RetVal|0x01);//DO_4 is bit 0 outp(0x53B,RetVal); system("pause"); //Reading DI_1~4 RetVal=inp(0x50C);//IO Port: 0x50C RetVal=(RetVal&0x3C);//DI_1 is bit 2 //DI_2 is bit 3 //DI_3 is bit 4 //DI_4 is bit 5 printf("DI_= %d\n",RetVal); system("pause"); return 0; KEMX-6000 User’s Manual...
Appendix B Appendix B WatchDog Timer Sample Code //============================================ //KEMX-6000 DOS Watchdog sample program //Please compile with Turbo C 3.0 to utilized the program //============================================ #include<stdio.h> int main() int value; //Initialized the WDT program outp(0x2E,0x87); outp(0x2E,0x87); //Setting Logical Device Number to 0x07 outp(0x2E,0x07);...
Page 67
Appendix B outp(0x2E,0xF0); outp(0x2F,0x81);//bit7 WDTRST# output is enabled return 0; KEMX-6000 User’s Manual...