Quanmax KEMX-8000 Series User Manual

Standard / extended temperature industrial motherboard in mini-itx form factor with intel haswell processors and hm87 / qm87 express chipset
Table of Contents

Advertisement

Quick Links

KEMX-8000 Series
Standard / Extended Temperature
Industrial Motherboard in Mini-ITX form factor
®
with Intel
Haswell Processors
and HM87 / QM87 Express Chipset
User's Guide
KEMX-8000 Series User's Manual
I

Advertisement

Table of Contents
loading

Summary of Contents for Quanmax KEMX-8000 Series

  • Page 1 KEMX-8000 Series Standard / Extended Temperature Industrial Motherboard in Mini-ITX form factor ® with Intel Haswell Processors and HM87 / QM87 Express Chipset User’s Guide KEMX-8000 Series User’s Manual...
  • Page 2 © 2013 Quanmax Inc. All rights reserved. The information in this user’s guide is provided for reference only. Quanmax does not assume any liability arising out of the application or use of the information or products described herein. This user’s guide may contain or reference information and products protected by copyrights or patents and does not convey any license under the patent rights of Quanmax, nor the rights of others.
  • Page 3: Table Of Contents

    Memory Module Installation............... 47 Chapter 4 AMI BIOS Setup..................48 Overview ....................48 Main Menu....................49 Advanced Menu..................50 Boot Menu ....................60 Security Menu.................... 61 Save & Exit Menu ..................61 Chapter 5 Driver Installation .................. 63 KEMX-8000 Series User’s Manual...
  • Page 4: Figures

    Figure 5 Rear Panel IO ................26 Figure 6 Expansion Interfaces ..............46 Figure 7 Align the SO-DIMM Memory Module with the onboard socket..47 Figure 8 Press down on the SO-DIMM Memory Module to lock it in place 47 KEMX-8000 Series User’s Manual...
  • Page 5: Tables

    Tables Tables Table 1 KEMX-8000 Series Specification........... 17 Table 2 Jumper List..................23 Table 3 JP2 RTC Reset Selection.............. 23 Table 4 JP3 MPCIE Activity LED Indication..........23 Table 5 JP4 SRTC Reset Selection ............24 Table 6 JP5 Flash Description Security Over-ride........24 Table 7 JP6 Backlight Power Enable Selection for LVDS1......
  • Page 6 Table 63 Advanced Menu –Super IO Configuration – ........ 58 Table 64 Advanced Menu –H/W Monitor............ 59 Table 65 Boot Menu ................... 60 Table 66 Security Menu ................61 Table 67 Save & Exit Menu ................ 61 KEMX-8000 Series User’s Manual...
  • Page 7: Safety Instructions

    Use extreme caution when installing or removing components. Refer to the installation instructions in this user’s guide for precautions and procedures. If you have any questions, please contact Quanmax Post-Sales Technical Support. WARNING High voltages are present inside the chassis when the unit’s power cord is...
  • Page 8: Preventing Electrostatic Discharge

    Static electricity can harm system boards. Perform service at an ESD workstation and follow proper ESD procedure to reduce the risk of damage to components. Quanmax strongly encourages you to follow proper ESD procedure, which can include wrist straps and smocks, when servicing equipment.
  • Page 9 Handle components and boards with care. Don’t touch the components or contacts on a board. Hold a board by its edges or by its metal mounting bracket. Do not handle or store system boards near strong electrostatic, electromagnetic, magnetic, or radioactive fields. KEMX-8000 Series User’s Manual...
  • Page 10: Preface

    Remove all items from the box. If any items listed on the purchase order are missing, notify Quanmax customer service immediately. Inspect the product for damage. If there is damage, notify Quanmax customer service immediately. Refer to “Warranty Policy” for the return procedure.
  • Page 11: Warranty Policy

    Quanmax or its authorized agent; or if the failure is caused by accident, acts of God, or other causes beyond the control of Quanmax or the manufacturer. Neglect, misuse, and abuse shall include any installation, operation, or maintenance of the product other than in accordance with the user’s guide.
  • Page 12: Maintaining Your Computer

    Quanmax. Limitation of Liability In no event shall Quanmax be liable for any defect in hardware, software, loss, or inadequacy of data of any kind, or for any direct, indirect, incidental, or consequential damages in connection with or arising out of the performance or use of any product furnished hereunder.
  • Page 13 Line conditioners keep a system’s AC power source voltage at a fairly constant level and, therefore, can handle brownouts. Because of this added protection, line conditioners cost more than surge protectors. However, line conditioners cannot protect against a complete loss of power. KEMX-8000 Series User’s Manual...
  • Page 14 Surge protectors should be used with all UPS systems, and the UPS system should be Underwriters Laboratories (UL) safety approved. KEMX-8000 Series User’s Manual...
  • Page 15: Chapter 1 Introduction

    Introduction Overview The KEMX-8000 Series is a Mini-ITX form factor industrial motherboard combining the latest 4th generation Intel® Haswell Core i processors with the high integration of the Intel® HM87 / QM87 chipset. Featured are 2x DDR3/L SO-DIMM, 2x LVDS, HDMI, DVI-D, VGA, 2x Gigabit Ethernet, 6x SATA, 6 x USB3.0, 6x USB2.0, 2x Mini...
  • Page 16: Product Specifications

    1x Header for Reset button, HDD LED and External Speaker support 1x Header for Power button, Power LED and SM bus support 1x Header for mPCIE activity LED support 1x Header for 8-bit DIO support Power 1x ATX Power Connector for 9-24VDC input KEMX-8000 Series User’s Manual...
  • Page 17: Table 1 Kemx-8000 Series Specification

    Storage Temp.: -20ºC ~ 80ºC / -4ºF ~ 176ºF (Standard) -40ºC ~ 85ºC / -40ºF ~ 185ºF (Extended) Humidity: 0% ~ 95% Real Time Clock Chipset integrated RTC Certifications CE, FCC Class A Table 1 KEMX-8000 Series Specification KEMX-8000 Series User’s Manual...
  • Page 18: System Block Diagram

    Chapter 1 System Block Diagram Figure 1 Block Diagram KEMX-8000 Series User’s Manual...
  • Page 19: Mechanical Dimensions

    Chapter 1 Mechanical Dimensions Figure 2 Mechanical Dimensions KEMX-8000 Series User’s Manual...
  • Page 20: Chapter 2 Hardware Settings

    No.1. To move a jumper from one position to another, use needle-nose pliers or tweezers to pull the pin cap off the pins and move it to the desired position. KEMX-8000 Series User’s Manual...
  • Page 21: Jumper Settings And Pin Definitions

    Chapter 2 Jumper Settings and Pin Definitions For jumper and connector locations, please refer to the diagrams below. KEMX-8000 Series User’s Manual...
  • Page 22: Figure 4 Jumper And Connector Locations

    Chapter 2 Figure 4 Jumper and Connector Locations KEMX-8000 Series User’s Manual...
  • Page 23: Jumper Settings

    Table 3 JP2 RTC Reset Selection Jumper Status 1-2 Open Normal Operation 1-2 Short Clear RTC CMOS Pitch:2.54mm [YIMTEX 3321*02SAGR(6T)] Table 4 JP3 MPCIE Activity LED Indication Description LED+ LED- DIP 2P 1R MALE STRAIGHT TYPE Pitch:2.54mm [YIMTEX 3321*02SAGR(6T)] KEMX-8000 Series User’s Manual...
  • Page 24: Table 5 Jp4 Srtc Reset Selection

    Pin 1 = DCD 2-4 Short Pin 9 = +12V 4-6 Short Pin 9 = +5V 6-8 Short Pin 9 = +5V 8-10 Short Pin 9 = RI SMD 10P 2R MALE TYPE 180D P-2.0mm [PINREX 222-97-05GBB1] KEMX-8000 Series User’s Manual...
  • Page 25: Table 9 Jp9 Signal / Power Selection For Com5

    Table 10 JP10 AT_ATX Mode / USB POWER Selection Jumper Setting Status ATX Mode (Default) AT Mode USB power will be cut off in S4 & S5 state (Default) USB power is always supply. SMD 6P 2R MALE TYPE 180D P-2.0mm[PINREX 222-97-03GBB1] KEMX-8000 Series User’s Manual...
  • Page 26: Rear Panel Pin Assignments

    Table 12 CN3 LAN1 & USB3.0 Port 1,2 Connector Signal Signal MDI[0]+ +USBVCC MDI[0]- USB_A- MDI[1]+ USB_A+ MDI[1]- MDI[2]+ +USBVCC MDI[2]- USB_B- MDI[3]+ USB_B+ MDI[3]- [UDE RU1-161F9WGF(XB)] * The power source of +USBVCC can be selected by JP10 KEMX-8000 Series User’s Manual...
  • Page 27: Table 13 Cn4 Lan2 & Usb3.0 Port 3,4 Connector

    Table 14 CN13 CRT DB-15 & DVI-D Connector Signal Name Signal Name Green Blue DDC_DATA HSYNC VSYNC DDC_CLK Signal Name Signal Name TX2- TX2+ DDC_CLK DDC_DATA TX1- TX1+ HTPLG TX0- TX0+ TXC+ TXC- [FAN YING G205D2C01012PHN] KEMX-8000 Series User’s Manual...
  • Page 28: Table 15 Cn14 Rs-232 / 422 / 485 Port 1, 2 Connector

    Note RS-232 / 422 / 485 can be selected in BIOS setup. Table 16 AUDIO1 3 Stack-up Azalia Audio Phone Jack Signal Name GREEN LINE OUT PINK MIC IN JACK*2 DIP 9P 90D AZALIA.D3.5mm [KORTAK ZJ387S-9B-7H] KEMX-8000 Series User’s Manual...
  • Page 29: Table 17 Hdmi1 Hdmi Connector

    TMDS Data1– TMDS Data0+ Ground TMDS Data0– TMDS Clock+ Ground TMDS Clock– Reserved Reserved DDC_CLK DDC_DATA Ground +5 V Power Hot Plug Detect [ARGOSY HDMIV-A1915-DK2R] Table 18 J1 Power Input DC Jack 2.5mm, Screw M8.0xP0.75/5.7mm, 9-24V KEMX-8000 Series User’s Manual...
  • Page 30: Internal Connector List

    SATA2 Serial ATA Port 1 Connector Serial ATA Port 2 Connector SATA3 Serial ATA Port 3 Connector SATA4 SATA5 Serial ATA Port 4 Connector SATA6 Serial ATA Port 5 Connector SIM1 SIM Interface Wafer for MPCIE2 KEMX-8000 Series User’s Manual...
  • Page 31: Table 19 Atx1 4-Pin Atx Power Input Connector

    Digital Output 1 Digital Input 1 Digital Output 2 Digital Input 2 Digital Output 3 Digital Input 3 Pitch:2.54mm [YIMTEX 3362*05SANGR] Table 23 CN6 Left Channel 3W Audio AMP Output Wafer Signal Name Speaker+ Speaker- Pitch:2.0mm [YIMTEX 503PW1*02STR] KEMX-8000 Series User’s Manual...
  • Page 32: Table 24 Cn7 Usb3.0 Port 5,6 Pin Header

    * The power source of +USBVCC can be selected by JP10 Table 26 CN9 USB2.0 Port 8, 9 Pin Header Signal Name Signal Name +USBVCC +USBVCC USB_A- USB_B- USB_A+ USB_B+ Pitch:2.54mm [YIMTEX 3362*05SANGR-09] * The power source of +USBVCC can be selected by JP10 KEMX-8000 Series User’s Manual...
  • Page 33: Table 27 Cn10 Usb2.0 Port 10,11 Pin Header

    DCD, Data carrier detect RXD, Receive data TXD, Transmit data DTR, Data terminal ready GND, ground DSR, Data set ready RTS, Request to send CTS, Clear to send RI, Ring indicator NC, Key Pitch:2.54mm [YIMTEX 3362*05SANGR-10] KEMX-8000 Series User’s Manual...
  • Page 34: Table 30 Cn17 Rs-232 Port 4 Pin Header

    TXD, Transmit data DTR, Data terminal ready GND, ground DSR, Data set ready RTS, Request to send CTS, Clear to send RI, Ring indicator / +12V / +5V * NC, Key Pitch:2.54mm [YIMTEX 3362*05SANGR-10] * Selected by JP9. KEMX-8000 Series User’s Manual...
  • Page 35: Table 32 Cn19 Rs-232 Port 6 Pin Header

    * Selected by JP7. Table 33 DIMM1 Primary DDR3 Memory SO-DIMM Socket Height:9.2mm [ARGOSY DDRSK-20401-TP9D] Table 34 DIMM2 Secondary DDR3 Memory SO-DIMM Socket Height:5.2mm [ARGOSY DDRSK-20401-TP5B] Table 35 FAN1 System FAN Wafer Signal +12V FAN_RPM Pitch:2.54mm [YIMTEX 521AW1*03STR] KEMX-8000 Series User’s Manual...
  • Page 36: Table 36 Fan2 Cpu Fan Wafer

    Note Internal Buzzer is enabled when Pin6-8 is shorted. Table 38 FP2 Front Panel 2 Pin Header Signal Signal Power LED + Power Button + Power Button - Power LED - SMBALERT# BATLOW# SMBus Data SMBus Clock Pitch:2.54mm [YIMTEX 3362*05SANGR] KEMX-8000 Series User’s Manual...
  • Page 37: Table 39 Lvds1 Primary 24-Bit, 2-Channel Lvds Panel Connector

    Table 39 LVDS1 Primary 24-bit, 2-channel LVDS Panel Connector Signal Name Signal Name TxoutB0- TxoutA0- TxoutB0+ TxoutA0+ TxoutB1- TxoutA1- TxoutB1+ TxoutA1+ TxoutB2- TxoutA2- TxoutB2+ TxoutA2+ TxclkB- TxclkA- TxclkB+ TxclkA+ TxoutB3- TxoutA3- TxoutB3+ TxoutA3+ TxoutB4- TxoutA4- TxoutB4+ TxoutA4+ SMD Male/30PIN/2ROWS/Pitch:1.25mm/NY-9T [Chyao-Shiunn JS-1256-15x2] KEMX-8000 Series User’s Manual...
  • Page 38: Table 40 Lvds2 Primary 24-Bit, 2-Channel Lvds Panel Connector

    SMD Male/30PIN/2ROWS/Pitch:1.25mm/NY-9T [Chyao-Shiunn JS-1256-15x2] Table 41 LVDS3 LVDS Panel POWER & CONTROL Connector Signal Name Signal Name +12V +12V +12V +12V +3.3V +3.3V +3.3V +3.3V VOL_ADJ BL_EN PWM_ADJ ENAVDD SMD MALE 20P 180° 2ROWS Pitch:1.25mm Tin Plated [HOMETOM WF20H6-7AJA178] KEMX-8000 Series User’s Manual...
  • Page 39: Table 42 Mpcie1 Mini-Pcie Express V1.2 Socket 2

    W_Disable# Ground PERST# PERn0 +3.3VSB PERp0 Ground Ground +1.5V Ground SMB_CLK PETn0 SMB_DATA PETp0 Ground Ground USB_D- Ground USB_D+ +3.3VSB Ground +3.3VSB LED_WWAN# Ground LED_WLAN# Reserved LED_WPAN# Reserved +1.5V Reserved Ground Reserved +3.3VSB Height:5.5mm [ARGOSY MPCEC-S00F1-TP03] KEMX-8000 Series User’s Manual...
  • Page 40: Table 43 Mpcie2 Mini-Pcie Express V1.2 Socket 1

    USB_D- Ground USB_D+ +3.3VSB Ground +3.3VSB LED_WWAN# Ground LED_WLAN# LPC_AD0* LED_WPAN# LPC_AD1* +1.5V LPC_AD2* Ground LPC_AD3* +3.3VSB Height:9.0mm [ARGOSY MPCEC-S00F1-TP09] * Internal debug only, left these pins open. ** These pins are connected to SIM1 directly. KEMX-8000 Series User’s Manual...
  • Page 41: Table 44 Peg1 Pcie Express X16 Slot

    PRSNT2# HSIN0 Ground Ground HSOP1 Reserved HSON1 Ground Ground HSIP1 Ground HSIN1 HSOP2 Ground HSON2 Ground Ground HSIP2 Ground HSIN2 HSOP3 Ground HSON3 Ground Ground HSIP3 Reserved HSIN3 PRSNT2# Ground Ground Reserved HSOP4 Reserved HSON4 Ground KEMX-8000 Series User’s Manual...
  • Page 42 Ground HSIN8 HSOP9 Ground HSON9 Ground Ground HSIP9 Ground HSIN9 HSOP10 Ground HSON10 Ground Ground HSIP10 Ground HSIN10 HSOP11 Ground HSON11 Ground Ground HSIP11 Ground HSIN11 HSOP12 Ground HSON12 Ground Ground HSIP12 Ground HSIN12 HSOP13 Ground KEMX-8000 Series User’s Manual...
  • Page 43: Table 45 Sata1 Serial Ata Port 0 Connector

    HSOP15 Ground HSON15 Ground Ground HSIP15 PRSNT2# HSIN15 Reserved Ground Pitch:1.0mm [WIN WIN WPCS-164AN41B22UWL] Table 45 SATA1 Serial ATA Port 0 Connector Signal Name DIP SATA-7P 180D CONN. BLUE/double row pin/parallel positioning peg [WIN WIN WATM-07ABN4A2B8UW4] KEMX-8000 Series User’s Manual...
  • Page 44: Table 46 Sata2 Serial Ata Port 1 Connector

    DIP SATA-7P 180D CONN. BLACK, double row pin/parallel positioning peg [WIN WIN WATM-07ABN4A2B8UW] Table 48 SATA4 Serial ATA Port 3 Connector Signal Name DIP SATA-7P 180D CONN. BLACK, double row pin/parallel positioning peg [WIN WIN WATM-07ABN4A2B8UW] KEMX-8000 Series User’s Manual...
  • Page 45: Table 49 Sata5 Serial Ata Port 4 Connector

    Table 50 SATA6 Serial ATA Port 5 Connector Signal Name DIP SATA-7P 180D CONN. BLUE/double row pin/parallel positioning peg [WIN WIN WATM-07ABN4A2B8UW4] Table 51 SIM1 SIM Card Socket for MPCIE2 Signal Name UIM_PWR UIM_RST UIM_CLK UIM_VPP UIM_DATA KEMX-8000 Series User’s Manual...
  • Page 46: Chapter 3 System Installation

    When adding or removing expansion cards, make sure that you unplug the power supply first. Meanwhile, read the documentation for the expansion card to configure any necessary hardware or software settings for the expansion card, such as jumpers, switches or BIOS configuration. KEMX-8000 Series User’s Manual...
  • Page 47: Memory Module Installation

    SO-DIMM. Lift it out of the socket. Make sure you store the SO-DIMM in an anti-static bag. The socket must be populated with memory modules of the same size and manufacturer. KEMX-8000 Series User’s Manual...
  • Page 48: Chapter 4 Ami Bios Setup

    This chapter provides a description of the AMI BIOS. The BIOS setup menus and available selections may vary from those of your product. For specific information on the BIOS for your product, please contact Quanmax. NOTE: The BIOS menus and selections for your product may vary from those in this chapter.
  • Page 49: Main Menu

    F2: Previous Values Total Size 2048 MB (DDR3) F3: Optimized Defaults Frequency 1600 MHz F4 Save & Exit System date [Wed 10/29/2014] ESC Exit System time [10:56:28] Access Level Administrator Version 2.15.1236. Copyright (C) 2012, American Megatrends, Inc. KEMX-8000 Series User’s Manual...
  • Page 50: Advanced Menu

    Version 2.15.1236. Copyright (C) 2012, American Megatrends, Inc. Onboard LAN 1 Controller Options: Disabled, Enabled Onboard LAN 1 Boot Options: Disabled, Enabled Onboard LAN 2 Controller Options: Disabled, Enabled Onboard LAN 2 Boot Options: Disabled, Enabled Audio Controller Options: Disabled, Enabled KEMX-8000 Series User’s Manual...
  • Page 51: Table 54 Advanced Menu - Display Configuration

    Options:32M, 64M, 96M, 128M, 160M, 192M, 224M, 256M, 288M, 320M, 352M, 384M, 416M, 448M, 480M, 512M, 1024M DVMT Total Gfx Mem Options: 128M, 256M, MAX Primary IGFX Boot Display Options: VBIOS Default, CRT, DVI, HDMI Active LVDS Options: Disabled, Enabled KEMX-8000 Series User’s Manual...
  • Page 52: Table 55 Advanced Menu -Power Management Configuration

    Options: Disabled, EUP Enabled, DeepSX in S5, DeepSX in S4-S5, DeepSX in S3-S4-S5 Resume By PCIE Device Options: Disabled, Enabled Resume By RTC Alarm Options: Disabled, Enabled Watchdog Timer Configuration WDT Function [Disabled] Options: Disabled, Enabled KEMX-8000 Series User’s Manual...
  • Page 53: Table 56 Advanced Menu -Cpu Chipset Configuration

    Turbo Mode Options: Disabled, Enabled Hyper Threading Options: Disabled, Enabled Active Processor Cores Options: All, 1, 2, 3 Limit CPUID Maximum Options: Disabled, Enabled Execute Disable Bit Options: Disabled, Enabled Intel ® Virtualization Tech Options: Disabled, Enabled KEMX-8000 Series User’s Manual...
  • Page 54: Table 57 Advanced Menu -Sata Configuration

    SATA Controller(s) Options: Disabled, Enabled SATA Mode Selection Options: IDE, AHCI SATA Controller Speed Options: Default, Gen 1, Gen 2, Gen 3 Port Options: Disabled, Enabled SATA Device Type Options: Hard Disk Driver, Solid State Driver KEMX-8000 Series User’s Manual...
  • Page 55: Table 58 Advanced Menu - Intel Rapid Start Technology

    Version 2.15.1236. Copyright (C) 2012, American Megatrends, Inc. Legacy USB Support Options: Disabled, Enabled, Auto USB 3.0 Support Options: Disabled, Enabled XHCI hand-off Options: Disabled, Enabled EHCI hand-off Options: Disabled, Enabled USB Mass Storage Driver Support Options: Disabled, Enabled KEMX-8000 Series User’s Manual...
  • Page 56: Table 60 Advanced Menu -Dio Configuration

    F1: General Help DI_1 F2: Previous Values DI_2 F3: Optimized Defaults DI_3 F4 Save & Exit DI_4 ESC Exit DO_1 DO_2 DO_3 DO_4 Version 2.15.1236. Copyright (C) 2012, American Megatrends, Inc. User Configuration Options: Disabled, Enabled KEMX-8000 Series User’s Manual...
  • Page 57: Table 61 Advanced Menu - Super Io Configuration

    IO=2F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=3E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=2E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; Serial Port Type Options: RS232, RS422, R485 KEMX-8000 Series User’s Manual...
  • Page 58: Table 63 Advanced Menu -Super Io Configuration

    IO=2F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=3E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=2E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; Serial Port Type Options: RS232, RS422, RS485 KEMX-8000 Series User’s Manual...
  • Page 59: Table 64 Advanced Menu -H/W Monitor

    Options: Disabled, 80 C, 85 C, 90 C, 95 C FAN Configuration : CPU FAN Configuration CPU FAN Setting [Manual Mode] Options: Manual Mode, Auto Mode Manual Duty 255 System FAN Configuration System FAN Setting [Manual Mode] Options: Manual Mode, Auto Mode Manual Duty 255 KEMX-8000 Series User’s Manual...
  • Page 60: Boot Menu

    Options: On, Off UEFI Boot Options: Disabled, Enabled CAM Support Options: Disabled, Enabled Boot Option Filter Options: UEFI and Legacy, Legacy only, UEFI only DIMM Voltage Warming Options: Disabled, Enabled Keyboard Detect Warming Options: Disabled, Enabled KEMX-8000 Series User’s Manual...
  • Page 61: Security Menu

    Save Options Enter: Select Save Changes +- Change Opt. Discard Changes F1: General Help Restore Defaults F2: Previous Values F3: Optimized Defaults F4 Save & Exit ESC Exit Version 2.15.1236. Copyright (C) 2012, American Megatrends, Inc. KEMX-8000 Series User’s Manual...
  • Page 62 Load Optimal Default values for all the setup values. This option allows you to load failsafe default values for each of the parameters on the Setup menus, which will provide the most stable performance settings. The F8 key can be used for this operation. KEMX-8000 Series User’s Manual...
  • Page 63: Chapter 5 Driver Installation

    After you have finished assembling your system and connected the appropriate power source, power it up using the power supply and install the desired operating system. You can download the drivers for the KEMX-8000 Series from the Quanmax website at www.quanmax.com and install as instructed there.

Table of Contents