gledhill GB10 Installation And Servicing Instructions page 33

Table of Contents

Advertisement

'c'
Error
code
1
T_FLOW_OPEN
2
T_RETURN_OPEN
8
T_FLUE_OPEN
11
T_FLOW_SHORTED
12
T_RETURN_SHORTED
18
T_FLUE_SHORTED
13
REFHI_TOO_LO_ERROR
14
REFHI_TOO_HI_ERROR
15
REFLO_TOO_LO_ERROR
16
REFLO_TOO_HI_ERROR
19
E2PROM_READ_ERROR
20
FLAME_ERROR_2
21
PHASE_ERROR
22
50HZ_ERROR
42
WD_COMUNICATION_ERROR
51
RESET_BUTTON_ERROR
8.3.
SERIAL SOFTWARE
In order to check the control and to set the parameters in its E2PROM, serial software is provided. To use
this software a windows PC with serial port (COMP port) or a USB port is needed.
8.4.
INTERNAL WIRING DIAGRAM
The appliance wiring diagram is shown in diagram 8.3. Ensure that wiring details are followed when a PCAB,
wiring harness or components are changed.
VER: 02.3 _260505
Supplied By www.heating spares.co Tel. 0161 620 6677
Table 8.6 Blocking error codes
Int
no
48
Flow sensor, S1, open
47
Return sensor, S2, open
51
Flue sensor, S3, open
56
Flow sensor, S1, shorted
55
Return sensor, S2, shorted
59
Flue sensor, S3, shorted
28
Temperature measurement incorrect
29
Temperature measurement incorrect
30
Temperature measurement incorrect
31
Temperature measurement incorrect
0
Not able to read e2prom contents
33
Flame detected with a closed gas valve
41
Mains supply live and neutral are reversed
42
Mains frequency is not 50Hz
44
problems with communicating with watchdog
65
Reset button pressed to many times in a short time
Description
Page:33/41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gb15Gb30Gb20Gb25