Merging Horus User Manual page 17

Hide thumbs Also See for Horus:
Table of Contents

Advertisement

Line Output Level calibration
The DA8 and DA8P modules feature both hardware level settings in the form of 4 DIP switches per
output channel and a software fine adjustment to align the Analog Output levels to whatever
local/organization operational levels are mandated.
The Hardware settings will usually be set only once, at product installation, and only if the desired
Operating Line Level differs from the default ex-factory settings of +18 dBu for 0 dBFS.
Procedure for Hardware alignment:
1. Shut down your Horus and make sure that the Horus back panel Power is also switched OFF.
2. Unscrew all DA8 modules that need adjustment.
3. Pull gently out (5-7 cm is enough) to access the DIP Switches. There is one block of 4 dip switches
per channel. Channel 1 is labeled S1, channel 8 is labeled S8.
4. Set the DIP Switches as per the table legend printed on the DA8 module card
Output Level (dBu)
+24
+18
1
2
ON
Switch
S1 to S8
3
ON
4
www.merging.com/horus
+15
+12
ON
ON
ON
ON
ON
ON