REFS Menu (I/O & Sync)
This Sub Page menu is where you can view the Deviation and Jitter of the External Reference, as
measured by the Horus synchronization circuitry.
Frequency:
Delta:

PreAmp Menu

The PREAMP (A/D) menu becomes active if you have 1 or more AD8(P) modules installed in the Horus
unit, giving full access to the Input controls. Please see below for a description of the buttons available.
All
The long-term measured Frequency (in Hz) and deviation in ppm (parts per
million) between the signal the unit is locked on to and the internal reference.
The short-term (instantaneous) time offset between the reference signal and
the internal (considered as ideal) reference, measured in nanoseconds (ns).
In other words, the delta indicator over a RAVENNA network will report the
delta in ns between the master and the slave.
Active: Will select all 8 input channels for function and level grouping
Inactive: Adjustments to the input settings and level affect only the selected
channel only
Note the All button will group all inputs of the same type (Mic or Line)