Merging Horus User Manual page 72

Hide thumbs Also See for Horus:
Table of Contents

Advertisement

"Ethernet input: Audio packet still pending";
"Ethernet input: Audio pipeline too small";
"Ethernet input: Wrong sequence number";
"Ethernet input: CRC error";
"Ethernet input: Queue mux error";
"Ethernet input: Audio buffer too small";
"Ethernet input: SSRC mismatch"
Error on the incoming RAVENNA streams. There might be click on the physical output of the Horus.
Such a click could have occurred on one of the RAVENNA bank of 8 channels. Verify your set up,
mainly on the network side and afterwards clear the error. If the problem persists contact our support
team.
"Ethernet input: Unknown error";
"FPGA memory: Timeout";
"FPGA memory: Unknown error";
Contact Merging Support
"48V power failure: all A/D 48V forced off until next reboot"
The attached error message is displayed when:
1. 48V is malfunctioning
2. If there is a short circuit on 48V
If a MAJOR (by MAJOR, we mean that the threshold of short-circuit detection requires at least 10
Preamp inputs to be shorted simultaneously) 48V Phantom Power Supply short circuit is detected, 48V
is forced off on all A/D channels and the following error message is displayed.
Note: 48V will be forced off until reboot.
Note: the user 48V settings are not affected i.e. the UI still shows the 48V as configured by the user.
www.merging.com/horus
Horus User Manual
Page 72