9.11
ICE-ENTRY-100 device support loging of specific events. ICE-Entry-100 logs CLIP
event and alarm input events.
Log event consist of event type, time and telephone number or input number.
9.11.1 LOGN parameter
Parameter is used for defining the number of events printed out on PLOG request.
9.11.2 LOGI parameter
Parameter is used to define the media used for loging of events on ICE-ENTRY-
100. User can select between nonvolatile memory on ICE-ENTRY-100 or select
USB to transfer events directly via USB to PC.
9.11.3 ALC parameter
Parameter is used to control behavior when log on ICE-ENTRY-100 is full. User can
select between auto log clear or manual clear of log.
9.11.4 Table of parameters
Name
LOGN
LOGI
ALC
Example:
♦ Direct programming on the SIM card
Name
LOGN

EVENT LOGING

Number of log events for printing out
Log interface
Automatic log clear

Table 24: LOG parameters.