Wiring Requirements - Heat & Glo TIARAP-BK-IPI Installation Manual

Hide thumbs Also See for TIARAP-BK-IPI:
Table of Contents

Advertisement

B. wiring Requirements
Intellifire Plus Ignition System Wiring
• Plug the cord from the appliance junction box to 110-120
Vac for proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.1, IPI Wiring diagram.
• this appliance is equipped with an IntelliFire Plus™ control
valve which operates on a 6 volt/1.5 aMP system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the unit oR install 4 aa cell batteries
(not included) into the battery pack before use.
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries should
not be used as a primary long-term power source. Battery
polarity must be correct when installing batteries.
do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected to
permanent electrical service.
TO JUNCTION
BOX (110V)
MODULATION
Figure 8.1 IPI wiring Diagram
36
Heat & Glo • TIARAP-BK-IPI, TIARAP-BR-IPI, TIARAP-CES-IPI Installation Manual • 2344-980_R4 • 11/14
MODULE
FLAME
FLAME
IGNITER
SENSE
RC100
BATTERY PACK
6V DC
RC200
(OPTIONAL WALL CONTROLS)
RC300

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tiarap-br-ipiTiarap-ces-ipi

Table of Contents