Heat & Glo TIARAP-BK-IPI Installation Manual page 19

Hide thumbs Also See for TIARAP-BK-IPI:
Table of Contents

Advertisement

Class A Metal Chimney
Prior to installing the gas stove, ensure that the existing
chimney is functionally sound and clean.
have the chimney and adjacent structure inspected
and cleaned by qualified professionals. hearth & home
technologies recommends that NFI or cSIa certified
professionals, or technicians under the direction of
certified professionals, conduct a minimum of a NFPa
211 level 2 inspection of the chimney.
Replace component parts of the chimney and fireplace
as specified by the professionals.
EXISTING
METAL
CHIMNEY
SYSTEM
DIRECT VENT PIPE
Figure 4.12
1. Remove existing chimney cap.
2. Measure the distance from the top of the chimney to the
bottom of the ceiling support box, add 3 in. (76mm) to
this measurement, and cut a section of 4 in. (101mm)
flex pipe to that length (the flex should be fully extended).
3. connect the end of the flex pipe section to the underside
of the top adapter, using four sheet metal screws. See
Figure 4.13.
4. Pass the flex pipe down through the center of the
chimney system, and center the top adapter on the top
of the chimney pipe. drill four 1/8 in. (3mm) diameter
holes through the top adapter, and into the chimney top,
preferably from the side of the top adapter. ensure that
you are drilling into the metal on the chimney. twist lock
the high wind termination cap onto the top adapter. See
Figure 4.14 and Figure 4.15.
19
Heat & Glo • TIARAP-BK-IPI, TIARAP-BR-IPI, TIARAP-CES-IPI Installation Manual • 2344-980_R4 • 11/14
TERMINATION
CAP
TOP
ADAPTOR
FLASHING
4 in. (102mm)
FLEX PIPE
RETRO CONNECTOR
Flex Pipe
Figure 4.13
Figure 4.14
Drill Four 1/8 in. (3mm)
Diameter Holes
Figure 4.15
5. Pull the flex pipe down through the ceiling support box,
until it protrudes approximately 3 in. (76mm). connect
the flex pipe to the retro connector, and attach with sheet
metal screws.
6. Push the flex pipe back up into the ceiling support box,
center the retro connector, and attach it to the support
box with sheet metal screws.
7. the connection between the appliance and the retro
connector may be completed with sections of direct vent
pipe.
Top Adapter
Sheet Metal Screws
High Wind Termination
Cap
Sheet Metal Screws