B. Wiring Requirements
®
IntelliFire Touch
Ignition System Wiring
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.3, IntelliFire Touch Wiring Diagram.
• This appliance is equipped with an IntelliFire Touch
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery pack before use.
Figure 8.3 IntelliFire Touch Wiring Diagram
50
JUNCTION BOX
110-120 VAC
ADAPTER
ELECTRONIC CONTROL MODULE
RF MODULE
(FOR USE WITH OPTIONAL
REMOTE CONTROL)
Heat & Glo • 6000C-IFT, 8000C-IFT Installation Manual • 2502-980 Rev. M • 3/21
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
When using batteries as a power source, the 6-volt
transformer must be unplugged from the receptacle.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service.
FLAME
IGNITER
REMOTE CONTROL
SENSE
I
S
6 PIN
RED
APPLIANCE
ON/OFF
BLK
BRN
CONTROL
IFT-RC400
IFT-RC150
WIRELESS
(OPTIONAL)
WALL SWITCH
(OPTIONAL)
6V DC
BATTERY PACK
RED
BLK