Battery Voltage or Circuit Breaker
Problems
If the slideout room will not work:
Turn the Chassis Battery Disconnect switch
OFF and then ON again. This will, in many
cases, reset power to the slideout system.
he chassis battery may be low on charge.
Press and Hold the Battery Boost switch
(located on the dash) while pressing the
interior slideout control switch. This
momentarily connects the house batteries to
assist in slideout room operation.
The circuit breaker may be tripped. The
circuit breaker, labeled "Slideout Power" is
located on a panel on an interior wall of the
passenger side storage compartment just
behind or ahead of the entrance door.
• Status
• Motor
LED's
Direction
• Motor 1
Connection
Slideout Room Controller
(Located in a driver or passenger side
compartment, depending on model)
- Remove panel to access
10-8
• Mode
Button
• Motor 2
Connection
Error Codes
When an error occurs during slideout room
operation, the slideout control panel (located in
driver side compartment) will use LED display
lights to indicate where the problem exists.
For specific motor faults, the green LED light
will blink 1 time for Motor 1 and 2 times for
Motor 2. The red LED light will blink from 2 to
9 times, depending on the error code. The error
codes are as follows:
(2) - BATTERY DROP OUT. Battery
capacity low enough to drop below 6 volts
while running.
(3) - LOW BATTERY. Voltage below 8 volts
at start of cycle.
(4) - HIGH BATTERY. Voltage greater than
18 volts.
(5) - EXCESSIVE MOTOR CURRENT.
High amperage (also indicated by one side of
slideout room continually stalling).
(6) - MOTOR SHORT CIRCUIT. Motor or
wiring to motor has shorted out.
(8) - HALL SIGNAL NOT PRESENT.
Encoder is not providing a signal. This is
usually a wiring problem.
(9) - HALL POWER SHORT TO
GROUND. Power to encoder has been
shorted to ground. This is usually a wiring
problem.
NOTE: When an error code is present, the
slideout control panel needs to be reset.
Operating the Extend/Retract switch will
reset the slideout control panel. Operate
the Extend/Retract switch again for
normal operation.
Manual Override
In the event that the slideout room fails to
retract and manual operation is required:
Locate the slideout control panel (located in
driver side compartment).