Electrical Adjustment
Grp / No. Item
200
Option
0 Logo Display Prohibition
1 RS232C Baud rate
4 CABLE SW
6 Device Refresh Disable
8 PJ-NET HUNGUP CHK
51 Filter Warning Display
53 Filter Counter Reset Times
54 Factory Default Executed Times
56 Menu Position (X)
57 Menu Position (Y)
72 COMPONENT/RGB SW
140 OFFSET ADD MODE
141 OFFSET ADD CHNG
142 OFFSET
143 TIMES OF OFFSET CHANGE
144 TIMES OF OFFSET RESET
201
Option (Signal) Not Used
0 FrameLock Option
204
Simulation mode
0 Scaler Enable
205
Spread Spectrum
0 Enable
1 Spread Rate
2 Spread Frequency
220
Projector Error Log
0 Warning_Log_1
: :
49 Warning_Log_50
50 Warning_Log Reset
235
Shutter
0 Power ON_OFF Motion
1 CMP_TRM
2 OUT_DLY_TRM
3 CMP_CHK_CNT
4 OPEN_DLY
5 CLOSE_DLY
6 Position Check Time
7 Stop Mode
8 Enable Close Cmd
10 Shutter Management Upper Time
240
Flow Calibration
0 Flow Calibration Exe
1 Flow Calibration Error Log
2 Clog Check Enable
3 Air Inlet Check Enable
5 Clog Auto Cooling Enable
6 Scroll Fail Auto Cooling Enable
8 Filter Counter Remaining Enable
13 Filter Stanbdard Limit
14 Filter Max Limit
LX1750 Service Manual
020-000643-01 Rev.1 (01-2014)
Function
0:Menu 1:Forced
0: 19200bps 1: 9600bps
Long Cable 0: Disable 1: Enable
0: Enable 1: Disable
0: Disable 1: Enable
1:On 0:Off
Read only
Read only
X Offset
Y Offset
0: Disable 1: Enable
Offset Tem Add Mode Display
0: No Addition, 1: Addtion
Apply Offset Change when the data is set 10
Offset Temp
Frame Lock Setting
0: OFF for PC
1: OFF for AV
2: OFF
3: ON Depending on Input Frequency
4: ON Depending on Input Frequency
0: Off, 1: On
0: Off, 1: On
Default 41
Default 0
Latest Error log
:
50th Error log
Log is cleared when the value is set to 10.
Shutter Warm - up Operation (0: Yes, 1: No)
Chattering Detecting Term
Output Term
Count of Information Sync
Open Output Delay
Close Output Delay
Position Check Time
Shutter Operation in Stop Mode
0:Free, 1:Brake
Shutter Close Command
0:Disable, 1:Enable
Flow Sensor Offset Calibration Start calibration when the value is
set to 1.
Log of Calibration Error (Read only)
255: Not Calibration
0: No Error
10: 1st Calibration Not Stable Airflow
11: 1st Calibration Out of Range
20: 2nd Not Stable Airflow
21: 2nd Out of Range
100: 10th Calibration Not Stable Airflow
101: 10th Calibration Out of Range
Filter Clogged Detection by Flow Sensor (0: Disable, 1: Enable)
Intake Vent Error Check (0: Disable, 1: Enable)
Cooling on Clog (0: Disable, 1: Enable)
Cooling on Scroll error (0: Disable, 1: Enable)
Filter Counter Remaining Function (0: Disable, 1: Enable)
Filter life (x100 hour)
Filter Limit (x100 hour)
Range
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 255
0 - 255
0 - 1024
0 - 1024
0 - 1
-
0 - 10
-
0 - 255
0 - 255
0 - 4
0 - 1
0 - 1
0 - 82
0 - 2
0 - 32767
:
0 - 32767
0 ~ 10
0 - 1
0 - 32767
0 - 32767
0 - 15
0 - 63
0 - 63
1 - 255
0 - 1
0 - 1
180 - 999
0 - 1
-
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 255
0 - 255
-87-
Initial
Note
0
0
0
0
0
1
0
0
0
0
1
0
0
10
0
0
4
0
1
41
0
0
:
0
0
Initial: 1 / Shipping: 0
7000
15000
5
0
0
30
0
1
480
0
255
Initial: 0 / Shipping: 1
Initial: 0 / Shipping: 1
1
1
1
Normal filter: 50
Special filter: 10
Normal filter: 60
Special filter: 15