SHTR
- When you activate this reset function, the fixture
shutter/dimmer motor.
1. Access the main menu.
2. Tap the UP button until "RESE" is displayed, press ENTER.
3. Tap the UP button until "SHTR" is displayed, then press ENTER to confirm.
4. The display will show "ON/OFF." Press the UP button to select "ON" to restart
the shutter/dimmer motor. Press ENTER to confirm.
5. Press MODE/ESC to return to the main menu.
OTHR
- When you activate this reset function, the fixture will only reset any motor not
specified in the other reset commands previously listed.
1. Access the main menu.
2. Tap the UP button until "RESE" is displayed, press ENTER.
3. Tap the UP button until "OTHR" is displayed, press ENTER to confirm.
4. The display will show "ON/OFF". Press the UP button to select "ON" to
reset the color motor. Press ENTER to confirm.
5. Press MODE/ESC to return to the main menu.
6. TIME MENU -
LIFE - Displays the fixtures total running time.
LAMP - Displays the lamp running time.
CLMP - Clears the lamp running time.
LIFE
- With this function you can display the total running time of the fixture.
1. Access the main menu.
2. Tap the UP button until"TIME"is displayed, press ENTER.
3. Tap the UP button until"LIFE"is displayed, press ENTER.