MENU SETUP
 For a PAL unit there are 11 different recording
rates you can select from: 50F/S (50 fields per
second), 25F/S, 17F/S, 10F/S, 5.5F/S, 2.9F/S,
1.52F/S, 0.88F/S, 1 F/4S, 1F/6S, and 1F/8S.
Please refer to the table in section 3.1 for
details.
NOTE: The 60 f/s (50 f/s for a PAL unit) recording
rate can only function in a 352x240
(352x288 for a PAL unit) resolution.
REC QUALITY:
This option determines the image quality to
be recorded. The DVR stores images in the
compressed format and allows the image
quality to be altered by the image size.
There are 4 levels of image quality you can
select from: BEST, HIGH, STANDARD, and
BASIC. Selecting the BEST image for use
provides higher-resolution recorded images,
and normally takes up more storage space
than a HIGH, STANDARD or BASIC image
does.
DISK FULL:
This option determines the way to utilize
storage media in case of a full disk.
REWRITE: When the hard disk is full, the
device continues recording by displacing the
old data.
STOP: When the hard -disk is full, the
device will stop recording.
AUDIO:
This option determines the way to record
sound if necessary.
OFF: Disables AUDIO recording.
11 KHz: Enables AUDIO recording.
22 KHz: Enables AUDIO recording.
NOTE: Audio function can only be activated at
the following refresh rates in NTSC(PAL):
60(50),
30(25),
20(17),
fields/sec.
( continued )

4.2 ALARM / MOTION Setting

10(10),
5.5(5.5)
31
MULTIPLEXER:
For optimum image recording please set this
option to ON when the DVR is connected to
a multiplexer for use. Set this option to OFF
when it is only connected to a single camera
or Quad processor.
MAIN MENU
RECORD
ALARM / MOTION
CLOCK/ TIMER
COMMUNICATION
DISK
SYSTEM
GOTO ALARM/ MOTION PAGE
This menu allows users to program the
configuration of alarm recording only when an
alarm input is activated. The device will
record as long as the alarm input is activated.
MAIN MENU
RECORD
ALARM / MOTION
CLOCK/ TIMER
COMMUNICATION
DISK
SYSTEM
GOTO ALARM/ MOTION PAGE
ALARM/ MOTION
: OFF
ALM OPERATION
REC RATE
: 30 F/S
: BEST
REC QUALITY
AUDIO
: OFF
ALM TYPE
: NO
ALM DURATION
: 0 SEC
PRE-ALARM
: OFF
MOTION SETTING
MAIN PAGE
ALM OPERATION:
This option determines whether to activate
/ deactivate the alarm recording when it
detects an alarm input.
ON: The device activates the alarm
recording when it detects an alarm input.