Machine Specifications - Thermal Arc Fabricator 140 Service Manual

Thermal arc fabricator 140; fabricator 180 welding machine
Table of Contents

Advertisement

INTRODUCTION

2.05 Machine Specifications

Description
Package System Part Number
Power Source Weight
Power Source Dimensions HxWxD
Number of Phases
Frequency
Flexible Supply Cable Size
Supply Lead Plug Type
Nominal Input Voltage
Rated Input Current
Rated kVA @ 100% Duty Cycle
Rated Input Current
Maximum Input Current
Generator Requirements
Supply VA @ max. output
Open Circuit Voltage Range
Output Current Range
Duty Cycle Period
Number of Output Voltage Values
Minimum Mains Circuit to suit factory fitted Plug
& Lead (Weld Current @ Duty Cycle)
Maximum Mains Circuit to suit factory fitted Plug
& Lead (Weld Current @ Duty Cycle)
Wire Size Range
^ The Rated Input Current should be used for the determination of cable size & supply requirements.
+ Motor start fuses or thermal circuit breakers are recommended for this application. Check local requirements for
your situation in this regard.
# Generator Requirements at the Maximum Output Duty Cycle.
January 25, 2008
Fabricator 140
W1002500
64 lb (29 kg)
7 ft (2.3 m) 14AWG
5-15P
120V AC
^ 15A
1kVA
15A (65A@40%)
24A (90A@20%)
# 6kVA
# 5.1kVA
20.5 – 34V
30 – 140A
4
(+) 15A (65A@40%)
(+) 24A (90A@20%)
Steel
Stainless Steel
.023" - .030"
(0.6 - 0.8mm)
Flux Core
.030" - .035"
(0.8 - 0.9mm)
Aluminum
.030" - .035" (0.8 - 0.9mm)
Table 2-1: Specifications
2-3
FABRICATOR 140, 180
Fabricator 180
W1002600
80 lb (36 kg)
15.8 x 10.0 x 21.3"
400 x 255 x 540mm
1
60Hz
8 ft (2.5 m) 12AWG
6-50P
230V AC
^ 21A
1.9kVA
21A (130A@25%)
31A (180A@15%)
# 8.5kVA
# 7kVA
19.5 – 38V
30 – 180A
10 Minutes
6
(+) 21A (130A@25%)
(+) 31A (180A@15%)
.023" - .030" - .035"
(0.6 - 0.8 - 0.9mm)
.023" - .030" - .035"
(0.6 - 0.8 - 0.9mm)
.030" - .035" - .045"
(0.8 - 0.9 - 1.2mm)
Manual 0-4992