Specifications - Thermal Arc 95S Operating Manual

Inverter arc welder
Table of Contents

Advertisement

THERMAL ARC 95 S
2.07 Specifi cations
Power Source Part Number
Welding Output
Welding Current Range
Nominal DC Open Circuit Voltage (OCV)
Welding Output, 104º F (40º C), 10 min.
(quoted fi gures refer to SMAW output)
Rated Input Current (A) for STICK Welding
Rated Input Current (A) for TIG Welding
Rated Output for STICK Welding
Rated Output for TIG Welding
Duty Cycle (%)
Welder Type
Output Terminal Type
Mains Power
Number of Phases
Nominal Supply Voltage
Nominal Supply Frequency
Effective Input Current (l1eff)
Maximum Input Current (l1 max)
Single Phase Generator Requirements
Classifi cation
Protection Class
Standards
Cooling Method
Dimensions and Weight
Welding Power Source Mass
Welding Power Source Dimensions (Height x Width x Depth)
Δ
The recommended time delay fuse or circuit breaker size is 30 amp. An individual branch circuit capable of
carrying 30 amperes and protected by fuses or circuit breaker is recommended for this application. Fuse size is
based on not more than 200 percent of the rated input amperage of the welding power source (Based on Article
630, National Electrical Code).
Thermal Arc continuously strives to produce the best product possible and therefore reserves the right to change, improve or
revise the specifi cations or design of this or any product without prior notice. Such updates or changes do not entitle the buyer of
equipment previously sold or shipped to the corresponding changes, updates, improvements or replacement of such items.
The values specifi ed in the table above are optimal values, your values may differ. Individual equipment may differ from the above
specifi cations due to in part, but not exclusively, to any one or more of the following; variations or changes in manufactured
components, installation location and conditions and local power grid supply conditions.
Manual 0-5086
5 - 95 Amps
50A / 22V @ 100%
80A / 23.2V @ 30%
90A / 23.6V @ 20%
Io=90A@23.6V
Iο = 90A @ 23.6V
Io = 95A@13.8V
90A / 23.6V @ 20%
95A / 13.8V @ 20%
20% @ 90A / 23.6V
Inverter Power Source
Single Phase
Δ 33.5 Amps
IEC 60974-1
9.7 lb. (4.4 kg)
H 13.0" x W 5.1" x D 9.0"
(H 330mm x W 130mm x D 230mm)
2-2
INTRODUCTION
W1003200
60V
33.5A
21.0A
Dinse 25
115V
50/60 Hz
15.0 Amps
6 KVA
IP23S
Fan Cooled
Introduction