Channel 6 – No function (when CH4 is set between 0-9
Channel 6 – Strobe (when CH4 is set between 10-255
0-255
Channel 7 – Dimmer intensity
0-255

Maintenance

The Showtec Compact Lightset requires almost no maintenance. However, you should keep the unit
clean.
Otherwise, the fixture's light-output will be significantly reduced.
supply, and then wipe the cover with a damp cloth. Do not immerse in liquid. Wipe lens clean with glass
cleaner and a soft cloth. Do not use alcohol or solvents. Keep connections clean. Disconnect electric
power, and then wipe the connections with a damp cloth. Make sure connections are thoroughly dry
before linking equipment or supplying electric power.
The operator has to make sure that safety-relating and machine-technical installations are to be
inspected by an expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are to be
inspected by a skilled person once a year.
The following points have to be considered during the inspection:
1. All screws used for installing the device or parts of the device have to be tightly connected and must
not be corroded.
2. There may not be any deformations on housings, fixations and installation spots.
3. Mechanically moving parts like axles, eyes and others may not show any traces of wearing.
4. The electric power supply cables must not show any damages or material fatigue.

Replacing a Fuse

Power surges, short-circuit or inappropriate electrical power supply may cause a fuse to burn out. If the
fuse burns out, the product will not function whatsoever. If this happens,
so.
1.
Unplug the unit from electric power
2.
Insert a screwdriver into the slot in the fuse cover.
3.
Remove the used fuse. If brown or unclear, it is burned
4.
Insert the replacement fuse into the holder where the old fuse was. Reinsert the fuse cover. Be sure to
use a fuse of the same type and specification. See the product specification label for details.

Troubleshooting

No Light

This troubleshooting guide is meant to help solve simple problems.
If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit
operates properly, do not carry out following steps.
If the light effect does not operate properly, refer servicing to a technician.
Response: Suspect three potential problem areas: the power supply, the LEDs, the fuse.
1. Power supply. Check that the unit is plugged into an appropriate power supply.
2. The LEDs. Return the Compact Lightset to your Showtec dealer.
3. The fuse. Replace the fuse. See page 21 for replacing the fuse.
4. If all of the above appears to be O.K., plug the unit in again.
5. If you are unable to determine the cause of the problem, do not open the Compact Lightset, as this
may damage the unit and the warranty will become void.
6. Return the device to your Showtec dealer.
Strobe effect, from slow to fast (0-20 flashes/sec.)
Gradual adjustment dimmer intensity from 0-100%
source.
)
)
Disconnect the mains power
Gently pry up the fuse cover.
out.
21
follow the directions below to do
The fuse will come
out.