5. F No. Standard Data Input
Compensate the unevenness of the iris meter sensitivity.
Mode
Subject
Adjustment Page
Adjustment Address
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: Refer to "Picture Frame Setting" for YH and YL.
Adjusting method:
Order Page Address Data
1
0
01
01
2
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
7
6
93
YH
8
6
01
79
9
6
07
10
6
01
00
11
6
01
BB
12
6
02
Note 3: The adjustment data will be automatically input to page:
F, address: 29 to 2D.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
00
2
6
2C
00
3
6
92
00
4
6
93
00
5
6
0
01
00
CAMERA
Clear chart
(Color reproduction adjustment
frame with the zoom lens at WIDE
end)
F
29 to 2D
Procedure
Perform "Data setting during
camera system adjustments".
(Refer to page 5-14)
(Note 2)
(Note 2)
Press PAUSE button.
Check the data changes to "01".
Press PAUSE button.
Press PAUSE button. (Note 3)
Check the data changes to "01".
Procedure
Press PAUSE button.
Release the data setting
performed at step 2 .
(Refer to page 5-14)
6. Mechanical Shutter Adjustment
Adjust the period which the mechanical shutter is closed, and com-
pensate the exposure.
Mode
Subject
Adjustment Page
Adjustment Address
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: Refer to "Picture Frame Setting" for YH and YL.
Adjusting method:
Order Page Address Data
1
0
01
2
3
6
2C
4
6
90
5
6
91
6
6
92
7
6
93
8
6
01
9
6
07
10
6
01
11
6
01
12
6
02
13
6
AB
Note 3: The adjustment data will be automatically input to page:
F, address: 5A, 6C to 7F and D4 to D8.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
2C
3
6
92
4
6
93
5
6
0
01
– 11 –
CAMERA
Clear chart
(Color reproduction adjustment
frame with the zoom lens at WIDE
end)
F
5A, 6C to 7F, D4 to D8
Procedure
01
Perform "Data setting during
camera system adjustments".
(Refer to page 5-14)
01
00
00
YL
(Note 2)
YH
(Note 2)
79
Press PAUSE button.
Check the data changes to "01".
00
Press PAUSE button.
AD
Press PAUSE button. (Note 3)
Check the data changes to "01".
Check the data changes to "00".
Procedure
00
Press PAUSE button.
00
00
00
Release the data setting
performed at step 2 .
(Refer to page 5-14)
00