3. F No. Standard Data Input

Compensate the unevenness of the iris meter sensitivity.
Mode
Subject
Adjustment Page
Adjustment Address
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Adjusting method:
1)
Shoot the Clear chart with the zoom WIDE end.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 5, address: F1, and set data: FF.
4)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
5)
Perform " Data setting during camera system adjustment".
(Refer to page 5-13)
6)
Select page: 6, address: 01, set data: BB, and press the PAUSE
button.
7)
(The F No. standard data input is performed and the stan-
dard data is stored in page: F, address: 29 to 2C)
8)
Select page: 6, address: 02, and check that the data is "01".
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
2)
Select page: 5, address: F1, and set data: 00.
3)
Select page: D, address: 63, set data: 00, and press the PAUSE
button.
4)
Release the data setting performed at step 5).
(Refer to page 5-13)
5)
Select page: 0, address: 01, and set data: 00.
STILL
Clear chart
(10 cm from the front of the lens)
F
29 to 2C

4. Mechanical Shutter Adjustment

Adjust the period which the mechanical shutter is closed,
and compensate the exposure.
Mode
Subject
Adjustment Page
Adjustment Address
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Adjusting method:
1)
Shoot the Clear chart with the zoom WIDE end.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 5, address: F1, and set data: FF.
4)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
5)
Perform " Data setting during camera system adjustment".
(Refer to page 5-13)
6)
Select page: 6, address: 01, set data: AD, and press the PAUSE
button. (The mechanical shutter adjustment is performed and
the adjustment data is stored in page: F, address: 5A and 6C
to 7F)
7)
Select page: 6, address: 02, and check that the data is "01".
8)
Select page: 6, address: AB, and check that the data is "00".
(If the data other than "00", mechanical shutter adjustment
has errors)
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
2)
Select page: 5, address: F1, and set data: 00.
3)
Select page: D, address: 63, set data: 00, and press the PAUSE
button.
4)
Release the data setting performed at step 5).
(Refer to page 5-13)
5)
Select page: 0, address: 01, and set data: 00.
5-16
STILL
Clear chart
(10 cm from the front of the lens)
F
5A, 6C to 7F