Venting System Components - Vermont Castings Intrepid INDVRCB Homeowner's Installation And Operating Manual

Vermont castings intrepid series direct vent, rear vent gas heater
Hide thumbs Also See for Intrepid INDVRCB:
Table of Contents

Advertisement

Intrepid® Direct Vent - Rear Vent Gas Heater
Fig. 16 Correct position of fan skirt installation.
Use the wire tie to secure the fan and rheostat wire
harnesses together to the tubing under the bottom
ST240
of the unit.
FDV attach fan
12/13/99 djt
Approved Vent System Components
The Intrepid Heater must be vented to the outdoors
through an adjacent exterior wall or through the roof. The
venting system must be comprised of the appropriate
listed venting components specified on this page. These
parts are available from DuraVent Corporation.
See Figure 4 for dimensions relevant to the standard min-
imum-vent kits.
DuraVent Components
www.duravent.com
Phone: 1-800-835-4429, Fax: 1-707-446-4740
Minimum Horizontal Vent Kit
Venting Component required for:
Basic Straight Through-the-Wall Installation
Horizontal Termination Cap
Vermont Castings Group Zero Clearance Sleeve (includ-
ed)
Firestop
Wall Thimble Cover
24" Straight (Maximum length)
Hardware Package (2 req'd)
NOTE: DuraVent Wall Thimble, 46DVA-WT is not ap-
proved for use with this appliance except in noncombus-
tible masonry walls.
For corner installation add:
45° Elbow, Blk.
Venting Components
90° Elbow, Blk.
45° Elbow, Blk.
6" Straight, Blk.
9" Straight, Blk.
8¹⁄₂" Pipe Extension, Blk
16" Pipe Extension, Blk
12" Straight
14
KT902
Fig. 17 Attach rheostat to bracket.

Venting System Components

24" Straight
36" Straight
48" Straight
Square Horizontal Termination Cap
Sconce Horizontal Termination Cap
Round Horizontal Termination Cap
Wall Plate
Vinyl Siding Standoff
Snorkel Termination - 14"
Snorkel Termination - 36"
Wall Strap
Cathedral Ceiling Support Box
46DVA-KHC
Storm Collar
Firestop Spacer
Flashing 0/12 - 6/12
46DVA-HRC
Flashing 6/12 - 12/12
Wall Thimble
54623
Wall Thimble Cover (Brass)
46DVA-WFS
Wall Firestop
46DVA-DC
Attic Insulation Shield
46DVA24B
Co-Linear Vent Adapter
56167
Steel Chimney Conversion Kit
Kit A (6B⁄," - 8B⁄,")
Kit B (6B⁄," - 10¹⁄₂")
Kit C (6B⁄," - 13")
Masonry Chimney Conversion Kit
Vertical Termination Cap (High Wind)
46DVA-E45B
Vertical Termination Cap (Low Profile)
*Included in Minimum Horizontal Vent Kit 46DVA-KHC
46DVA-E90B*
46DVA-E45B
All DuraVent Straight vent pipe sections have a net length
46DVA-06B*
1¹⁄₂" (37 mm) less than the nominal dimension; i.e., a 6"
46DVA-09B
(152 mm) Straight pipe section has an effective length of
46DVA-08AB*
4¹⁄₂" (115 mm).
46DVA-16AB
Refer to the DuraVent website for additional components.
46DVA-12
(www.duravent.com)
Retaining Nut
Rheostat Knob
ST347a
JUV
FK28
rheostat install
9/21/00
Rheostat
KT903
46DVA-24B*
46DVA-36B
46DVA-48
46DVA-HC
46DVA-HSC
46DVA-HRC
46DVA-DC*
46DVA-VSS
46DVA-SNK14
46DVA-SNK30
46DVA-WS
46DVA-CS
46DVA-SC
46DVA-FS
46DVA-F6
46DVA-F12
46DVA-WT*
3PVP-TKV
46DVA-WFS
46DVA-IS
46DVA-GCL
46DVA-KCA
46DVA-KCB
46DVA-KCC
46DVA-KMC
46DVA-VCH
46DVA-VC
20012761

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents