Clean Water Systems Fleck 5600 Softener Installation & Start?Up Manual page 15

Table of Contents

Advertisement

Unit used too much salt 
Loss of water pressure 
Loss of softening resin through drain line 
Iron in conditioned water 
Excessive water in brine tank 
Softener fails to draw brine 
Page 14 
Fleck 5600 Softener Installation & Startup Guide 
Internal valve leak
Improper salt setting.
Excessive water in brine 
tank. 
Iron buildup in line to 
water 
conditioner 
Iron buildup in water
conditioner. 
Inlet of control plugged 
due to foreign material 
broken loose from pipes 
by recent work done on 
plumbing system. 
Air in water system
Improperly sized drain 
line flow control. 
Fouled mineral bed.
Plugged drain line flow 
control 
Plugged injector system
Timer not cycling
Foreign material in brine 
valve 
Foreign material in brine 
line flow control. 
Drain line flow control is 
plugged 
Injector is plugged.
Injector screen plugged
Line pressure is too low
Internal control leak
Service adapter did not 
cycle. 
www.cleanwaterstore.com 
Replace seals and spacers and/or piston.
Check salt usage and salt setting
See problem 7.
Clean line to water conditioner. 
Clean control and add mineral cleaner to 
mineral bed. Increase frequency of 
regeneration. 
Remove piston and clean control
Assure that well system has proper air 
eliminator control. Check for dry well 
condition. 
Check for proper drain rate. 
Check backwash, brine draw, and brine tank 
fill. Increase frequency of regeneration. 
Increase backwash time. 
Clean flow control 
Clean injector and screen. 
Replace timer
Replace brine valve seat and clean valve.
Clean brine line flow control 
Clean drain line flow control 
Clean injector
Clean screen
Increase line pressure to 20 psi 
(1.3 bar) 
Change seals, spacers, and piston assembly.
Check drive motor and switches.
Rev 031714 