Final Checks; Trouble Shooting; Commissioning Checklist - Rinnai RF1200TW Operation & Installation Manual

Rinnai rf1200tw fireplace
Table of Contents

Advertisement

FINAL CHECKS

Check that the appliance operates properly in all modes (high & low gas rates, fan high & low.) and make sure that
all the supplied parts are used and properly installed.
It is important that the customer is fully aware of how to operate the appliance properly and safely. Advise the
customer to fully read the operation sections of this manual to understand how to get the best out of their appliance.
Advise the customer of the need for regular servicing in order to maintain the warranty.
Complete the Commissioning Checklist.

TROUBLE SHOOTING

Symptom
Front panel ON/OFF
button does not work (no
spark noise)
Remote control ON/OFF
button does not work
(no spark noise), yet
the front panel ON/OFF
button does work
Ignition is sparking then
locks out
Sparking continues,
after pilot flame ignites
Pilot ignites, yet main
flame does not
Flame goes out
Fan does not operate
* If the appliance fails to ignite after three (3) attempts, turn off the power and gas if possible and arrange for a
service call or contact the installer if the unit is newly installed.

COMMISSIONING CHECKLIST

To be completed by the installer
Serial Number ___________________________________________________________
1.
Is the appliance positioned in a suitable location with regards to clearances?
2.
Is the unit fixed in location?
3.
Is the burn media installed and positioned correctly?
4.
Have all gas connections been checked for leaks using a soapy water solution?
5.
Have you instructed the owner of the correct operation of this appliance before leaving?
6.
Have you left the operating instructions with the owner?
7.
Have you removed all PVC plastic coating material?
Ensure all PVC plastic coating material is removed before operating the unit.
If you have answered NO to any of the above questions you MUST NOT allow the appliance to be
WARNING
operated until the item has been rectified.
Rinnai
Possible Cause(s)
Mains Power Disconnected
Gas Control Locked Out
Faulty Control Mechanism
ON/OFF button not held for 1 second
Flat Batteries
Signal interference
Faulty remote control or receiver
Gas Control Locked Out
ON/OFF button not held for 1 second
Air in gas supply
Gas supply turned off or empty
Faulty flame rod
Dirty gas in cylinder (LPG/Propane)
Faulty gas control
Gas supply turned off or empty
Mains power disconnected
Accidental operation of remote control
Flat batteries in remote control
Faulty remote control or receiver
Faulty fan or wiring
Check mains supply & isolating switch
Press ON/OFF button twice to reset*
Hold ON/OFF button for at least 1 second
Move to another part of the room
Press ON/OFF button twice to reset*
Hold ON/OFF button for at least 1 second
Turn on gas supply or change gas cylinder
Replace or change over gas cylinder
Turn on gas supply or change gas cylinder
Check mains supply & isolating switch
Check location of remote control
24
Corrective Action(s)
Service Call
Replace Batteries
Service Call
Purge gas supply*
Service Call
Service Call
Replace Batteries
Service Call
Service Call
NO
RF1200TW OIM
YES

Advertisement

Table of Contents
loading