STEP 2:
A suitable exhaust hood must be installed above the range. The following chart indicates the
minimum blower capacity recommended for hood ventilation.
VENTILATION
UNIT
HOOD
BLOWER
* When installing a unit featuring a grill, select a blower on the high end of recommendation.
** For all 36" Range GL models a 1200 CFM ventilation unit is required.
CAUTION:
Ventilation hoods and blowers are designed for use with single wall ducting.
However, some local building codes or inspectors may require double wall
ducting. Consult local building codes and/or local agencies, before starting, to
ensure that hood and duct installation will meet local requirements.
Hood blower speeds should be variable to reduce noise and loss of heated or air conditioned
household air when maximum ventilation is not required. Normally, the maximum blower speed is
only required when using the grill.
For best smoke elimination, the lower edge of the hood should be installed a minimum of 30" to a
maximum of 36" above the range cooking surface, (page 10 & 11). If the hood contains any
combustible materials (i.e. a wood covering) it must be a minimum of 36" above the cooking surface.
Due to a high volume of ventilation air, a source of outside replacement air is recommended. This is
particularly important for tightly sealed and insulated homes. A reputable heating and ventilating
contractor should be consulted.
VENTILATION REQUIREMENTS
STANDARD COUNTER
INSTALLATION
RECOMMENDATIONS
(24" Deep x Unit Width)
(30" Deep x 36" at Bottom)
*48" RANGE
800-1200 CFM
**36" RANGE
600-800 CFM
30" RANGE
500 CFM
8
ISLAND
INSTALLATION
RECOMMENDATIONS
800-1200 CFM
600-1200 CFM
500 CFM