6. SERVICE, OPERATION DISTURBANCES

The amount of use and the working environment should be taken into consideration when planning
the frequency of maintenance of KWF. Careful use and preventive maintenance will help to ensure
trouble-free operation.
The following maintenance operations should be carried out at least every six months:
Check:
– The wear of the grooves of the feed rolls. Excessive wear of
grooves causes problems in wire feed.
– The wear of the wire guide tubes of wire feed. Badly worn
feed rolls and wire guide tubes should be discarded.
– The wire guide tube in the gun should be set as near the feed
rolls as possible, but not touching them and the wire must
follow a straight line from the end of the tube to the groove
of the feed roll.
– Reel brake adjustment.
– Electric connections
* Oxidised couplings must be cleaned
* Loose couplings must be tightened
Clean dust and dirt from the equipment.
When using compressed air, always protect your eyes with
proper eye protection.
In case of problems contact your KEMPPI dealer.

7. DISPOSAL OF THE MACHINE

Do not dispose of electrical equipment together with normal waste!
In observance of European Directive 2002/96/EC on Waste Electrical and Electronic
Equipment and its implementation in accordance with national law, electrical equipment
that has reached the end of its life must be collected separately and returned to an
environmentally compatible recycling facility. As the owner of the equipment, you should
get information on approved collection systems from our local representative.
By applying this European Directive you will improve the environment and human
health!
© KEMPPI OY
twice a year
WeldForce KWF 200S / 0541 – 19