eXtendo
Thermal Printer Family
12 VDC
10-36 VDC
Cutter:
Presenter (optional):
Dimensions (WxHxD):
Environmental Range
Operating:
Storage:
Part No. D 684 124
density (coverage) of 25%: 1.6 A avg.
With Hengstler paper, at 21° C ambient temperature, with a
print speed of 100 mm/sec, voltage of 24.0 VDC, and print
density (coverage) of 50%: 2.8 A avg.
With Hengstler paper, at 21° C ambient temperature, with a
print speed of 100 mm/sec, voltage of 12.0 VDC, and print
density (coverage) of 12.5%: 0.9 A avg.
With Hengstler paper, at 21° C ambient temperature, with a
print speed of 100 mm/sec, voltage of 12.0 VDC, and print
density (coverage) of 25%: 1.5 A avg.
With Hengstler paper, at 21° C ambient temperature, with a
print speed of 100 mm/sec, voltage of 12.0 VDC, and print
density (coverage) of 50%: 2.6 A avg.
With Hengstler paper, at 21° C ambient temperature, with a
print speed of 100 mm/sec, voltage of 12.0 VDC, and print
density (coverage) of 12.5%: 0.9 A avg.
With Hengstler paper, at 21° C ambient temperature, with a
print speed of 100 mm/sec, voltage of 12.0 VDC, and print
density (coverage) of 25%: 1.5 A avg.
With Hengstler paper, at 21° C ambient temperature, with a
print speed of 100 mm/sec, voltage of 12.0 VDC, and print
density (coverage) of 50%: 2.6 A avg.
Guillotine (full or partial cut) or Rotary Type (heavy stock)
Loop-type
100 x 100 x 100 mm (approx.)
-25 to +70ºC 20% to 100% RH, or
0 to +50ºC
25% to 80% RH, non-condensing
-30ºC to +75ºC
Mod. No. 4 080812 LEV