5.5 System parametres

Parametr
Value
61
In default the stages of door intercom are acoustically signalling. By parametr
„z" you can switch off this signalling. Possible values are
z=0 – signalling is off
z=1 – signalling is on
Parametr
Value
62
In default is signalling pick up and hang up of the line. If you identify some
problems at certain PBXs you can switch it off by parametr „v" . The possible
values are:
v=0 – signalling OFF HOOK / ON HOOK is off
v=1 – signalling OFF HOOK / ON HOOK is on (type 1)
v=1 – signalling OFF HOOK / ON HOOK is on (type 2)
Parametr
Value
63
In default it is switch off. By activation of this feature you can identify at PBX
calling from door intercom just up knocking into call. Possible values are:
u=0 – knocking to call is off
u=1 – knocking to call is on
Parametr
Value
64
In version /C only or at version (C) .
In default external power supply is OFF.
Activation has a sense only in cases when door intercom should make some
operation during stand by mode – relay activation. Relay in mode m=7 allows
permanent closing even after call termination. Relay mode m=8 allows
activation up DAY/NIGHT mode settings even after call termination. In those
cases you have to provide external power supply to dont flow current at hanged
up line. The DIP switch 3 and 4 must be in position „on" to activate this parametr
w=1 . Deactivation - w=0.
BRAVE – user guide
Description
Acoustic signalling
z
memory, call termination...)
Description
Acoustic signalling off hook/on hook
v
(0/1/2)
Description
u
Acoustic signalling knocking to call (0/1)
Description
Powering from external power supply 12V
w
(DIP 3,4)
(confirmation, error, empty
(0/1)
Default
1
Default
1
Default
0
Default
0
(0/1)