m=7 permanent closing / opening – usable at versions /C and (C) only, if
switching (DIP 3,4)+par.64. By command for pulse 1 is closed and for
pulses2 is opened. This stage stays in door intercom even after power/line
disconnection. This mode you can use for potting, glasshouse opening,
heating activation etc..
m=8 activated up DAY/NIGHT mode settings - usable at versions /C and (C)
only, if switching (DIP 3,4)+par.64. Version /C allows copying manual
DAY/NIGHT switching only. Version (C) allows copying setting from week
table switching time (when is activated - parametr 084) and then you can
use for example for heating control etc...
Parametr
Value
31
r* tt
– relay number [1-2]
r
tt – button number (memory), always has 2 digits [01-99]
This parametr is for relay mode m=6 only. Value of tt designate from which
button start closing for time t1/t4 of relay r.
Parametr
Value
32
rp hh...
33
rp hh...
34
rp hh...
– relay number [1-2]
r
– order [1 - 5] for 1 pulse. 5 passswords (external codes) from door
p
intercom buttons (external code of codelock)
– order = *, then you can insert just one code (external code) for closing
p
by 2 pulses
hh... – password (external code) for relay closing from buttons [2 to 6 digits].
Tlačítka 1 - 10 are programmable as numbers 1-0.
Totally 3 x 12 passwords. Controlled by settings DAY/NIGHT.
Combination is inserting by door intercom
by setup relay mode and switching DAY/NIGHT. When is setup mode 2 groups
of numbers the door intercom is permanently in mode DAY.
You have to keep certain rules for password dialling:
First button of password select from at least used button for direct
dialling (-prolong dial time)
30
Description
button tt start relay closing r in mode m=6
(01-99)
Description
In mode DAY + NIGHT password hh... for
relay r, in order p=1-5, for 1 pulse
and p=* for 2 pulses
In mode DAY password hh... for relay r, in
order p=1-5, for 1 pulse and p=* for 2
pulses
In mode NIGHT password hh... for relay r,
in order p=1-5, for 1 pulse and p=* for 2
pulses
(00-999999)
(00-999999)
(00-999999)
buttons.
Relay closing is influenced
BRAVE – user guide
Default
01
Default
-
-
-

Advertisement