Brave Smyle - C User Manual page 32

Door intercom
Table of Contents

Advertisement

Example: command to activate relay1 with 1 pulse *8, command to hang up *8 and
command for activation relay2 with 2 pulses *9.
Dial: 352*8 ♫ , 432*8 ♫ , 362*9 ♫.
You are in communication with door intercom unit. Dial command for open sliding gate 9.
First pulse starts sliding the gate and second pulse stop it. The size of spot for person
entrance is according time between each pulses (parametr 30). After person etnering you
dial 8. The door intercom makes one pulse and hang up. Sliding gate is closing.
Parametr
Value
37
r ss
– relay number [1-2]
r
ss – time t1 / t4 for which is relay closed 1 / 2 [2 digits 00-99], where time 00
means 0,5sec
Parametr
Value
38
r p
– relay number [1-2]
r
p – parametr which says permitted p=1 or forbidden p=0 control relay during
incoming call
To prohibit control of relay during incoming call has a sense for example by
relay2 in mode 1 by which you control sliding gate opening where door intercom
open the gate and after car passing the gate is closed. Then control by phone
could make unwillingly permanent gate opening.
Parametr
Value
39
xx – time t3 between activation relay 1 and 2 when mode m=5 is setup
(progressive opening) [2 digits 00-99] ], when time 00 means 0,5sec
Parametr
Value
30
r zz
– relay number [1-2]
r
– time t2 / t5 between first and second pulse relay activation 1 / 2 [2 digits
zz
00-99], where 00 means 0,5sec
32
Description
time ss [sec] activation relay r for time t1/t4
(00-99)
Description
Control relay r during incoming call
Description
time xx [sec] between activation relay 1
xx
and 2 in mode m=5 - time t3
(01-99)
Description
time zz [sec] between pulses when is
closing for 2 pulses relay r - time t2/t5
(00-99)
Default
105 205
Default
(0/1)
Default
Default
105 205
BRAVE – user guide
11 21
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smyle - c/cSmyle - lc

Table of Contents