Settings examples:
1.
first button should dial at DAY number 358 and in NIGHT 0_603441296 , you
programm it - 101358 and wait for ♫, next 2010 *0 603441296 and wait for ♫
2. second button should dial at DAY and NIGHT 123#1*2Flash3, you programm
102123#1 ** 2 *# 3 and wait for ♫, next 202123#1 ** 2 *# 3 and wait for ♫
Note. When you dont use mode of 2 group numbers or DAY/NIGHT mode we
recommend setup DAY/NIGHT mode (parametr 47) and next setup same code for
DAY/NIGHT switching (parametry 45 and 46). You provide by this that door intercom
will be always in DAY mode and then you programm numbers for DAY mode only
(parametr 1).

5.2 Relay(s)

Parametr
Value
31
r m
– relay number [1-2]
r
m – relay mode [1-8 for r=1 is not mode m=5]
modes m=1,4,5,6 are detaily descriped in Tab. 1. on page 24
m=1 mode relay – activated by command (internal code) or password (external
code) 1 pulse for time t1/t4 (using for electrical locks) or 2 pulses when is
activated for time t1/t4, open for time t2/t5 and close for time t1/t4 (sliding
door opening)
m=2 closed for time of line OFF HOOK (camera) – close when door intercom
picks up and open by hanging up
m=3 closed for time of line OFF HOOK and more for time t1/t4 after hang up
(lighting) – closed when door intercom picks up and stays closed for time
t1/t4 after door intercom hangs up (for this time line is busy, at version /C
and C is after switching DIP 3,4 and settings parametr 64 for time t1/t4
line hanged up)
m=4 mode button – closed when any button is pushed and open after time
t1/t4 (usage for example: connection external bell)
m=5 mode progressive opening – you can setup into this mode relay 2 only
because relay 1 will be setup automatically into mode m=1. By command
(internal code) or password (external code) is activated relay 1 for time t1,
then is running time t3 before closing relay 2. Then is relay 2 activated for
time t4 and then door intercom hangs up. When dialled command or
password match to 2 pulses then in sequence will appear two pulses
separated by time t2/t5. Explained in Tab. 1
Note. The command or password for relay 1start whole sequence.When you use
command or password for relay 2 then you control relay 2 only the same like in
mode m=1.
m=6 closed up pushed button (setup in parametr 31r*). Due this you can select
one button for every relay its pushing activate appropriate relay for time
t1/t4. This mode serves as substitution of ring bell connected to Brave
system.
BRAVE – user guide
Description
relay r works in mode m
Deafault
11 21
(1-8)