Page 1
Brave – Door Intercom Brave Smyle - C Brave Smyle - LC Brave Smyle - C/C User guide Version 2.6...
Page 3
Dear customer Congratulation to your purchase of “BRAVE SMYLE door intercom”. The BRAVE Smyle door intercom is designed as universal project to be suitable for different installation on the field and brings more features and possibilities. This manual is designed for Urmet 1129 panel in 4 models with 1 or 2...
Programming by phone DTMF or by USB cable from PC Integrated heating for PCB Permanent cards lighting, switchable Ground output for better protection against static electricity (C) – comfort model only (Comfort) /C - model with camera only BRAVE – user guide...
PBX extension) The manufacturer continuously improves the product firmware. The technology used allows you to upload to Brave the latest version of the firmware any time using a standard computer with BraveSet and USB cable. The latest version of the firmware is available at http://www.alphatech.cz...
1.3 Different Models of Smyle Brave door intercom Brave door intercoms is designed as new generation of door intercom units reflects all experiences collected during last 10 years of succesfull sales of door enry solutions. Features and parametres are different for different models of intercom to provide best balance between price and usage value.
All functional and connectional elements are marked by red rounded number at bellow picture. Explanation follow on next page. Pict. 1 Brave Smyle mother board (1) + (3) + (7) + (11) - version /C only relay 2 version (C) only...
Page 10
The power supply might be AC as same as DC, not depends on polarity, max consumption 250mA from 12V. The power supply might be used also for electrical lock powering. Then we recommend power supply 12V/1A. BRAVE – user guide...
Page 11
RFID, etc.. The heating has control element to restrict power. The remaining components are designed for voltage up 24V DC!!! It not depends on polarity. BRAVE – user guide...
2.1.2 Assembly of cards backlighting 2.1.3 Wall mounting of Brave Smyle Make the mounting by attached pack with screws and plug (drill 5mm). BRAVE – user guide...
2.1.4 Replacing of cards backlighting after wall mounting 2.1.5 Cards exchange (name cards) Every button has own card ( label) holded by plastic flag ( via picture). You can print out paper labels from special Excel file (downloadable on www.alphatech.cz or ). BRAVE – user guide...
The basic functionality of intercom (voice communication) needs connection of telephone line only - LINE (8) on .Pict. 1 Brave Smyle. The line is connected by 2 wires (a,b) and in stand by has usually voltage 24V - 60V, short circuit current 20mA - 60mA. When line is OFF HOOK the line voltage is 7V - 10V.
2 m=5 - version (C) only. 2. Two power supply – possibility to use independently two power supply One for Brave Smyle and second for electrical locks. Second electrical lock is connected inversaly (fire emergency exit). 3. Combination of doors with electrical lock and sliding gate at fencing.
Page 17
Pict. 2 Examples of relay connection BRAVE – user guide...
You just registrate intercom as handset to DECT base station. All features of intercom are kept. Important: DECT base station must support DTMF transmission between each handsets (relay activation feature). BRAVE – user guide...
2.4.4 Power supply 12V As standard we provide for Brave Smyle intercom AC power supply 12V/1A . It is not part of unit packaging. It must be ordered individualy. More info about electrical locks and power supply on www.alphatech.cz. 2.4.5 Programming cable USB USB cable is not part of packaging.
3 Door intercom service Functionality of Brave Smyle door inercom is adjustable by parametres settings (via. Programming parametres capture page 26). 3.1 Signalling overview The Brave Smyle door intercom signalling acoustically stages which are happening during operation. Samples of acoustical sounds you can play in BraveSet ( PC programm).
When call duration is longer then setup limit (parametr 52) the 10sec before hang up Brave intercom sends alerting tone of call ending. Mr. Scott can dial * or # up setting (parametr 42) to prolong the call about the time setup by parametr 52.
Page 23
332* According settings DAY/NIGHT 342* Internal code from phone You can dial 1 or 2 numbers of code 2digits code is default You can shorter it by using * on first digit of code during programming BRAVE – user guide...
Tab. 1 Table of relay(s) control 3.3 Person inside building By person inside building we mean person in telephone connection with Brave intercom , for example Mr. Scott. 3.3.1 Outgoing call Outgoing call is a call from door intercom (generated by visitor). After door intercom dial is ringing a phone inside the building.
We choose when the direction to the phone is interrupted. If parameter 73 greater than parameter 72, thus favored direction to the speaker. We choose this if the interrupted sound in the speaker of communicator. BRAVE – user guide...
When you enter programming mode and do not make any dialling for 30seconds the door intercom will hang up. After each dialled DTMF tone the time is prolonged about 30seconds. You can finish programming mode also by dialling parametr 9. BRAVE – user guide...
Details about setting you will find in programm HELP and on website www.alphatech.cz. USB cable is special cable with galvanical isolation and with 3V convertor. The galvanical isolation is neccessary because telephone line must not be grounded and PC´s are usually grounded. BRAVE – user guide...
(C) this mode switch up current time (when this feature is activated - parametr 084) Note: at version Brave Smyle - C and Brave Smyle - LC are available max. 2 buttons - tt=01-02 BRAVE – user guide...
(setup in parametr 31r*). Due this you can select one button for every relay its pushing activate appropriate relay for time t1/t4. This mode serves as substitution of ring bell connected to Brave system. BRAVE – user guide...
Page 30
DAY. You have to keep certain rules for password dialling: First button of password select from at least used button for direct dialling (-prolong dial time) BRAVE – user guide...
Page 31
(star represents empty character and must be on first digit position). Activation relay 2 pulses is suitable for example: at sliding gate which this way can also substitute wicket for person entrance. BRAVE – user guide...
Page 32
2 pulses relay r - time t2/t5 105 205 (00-99) – relay number [1-2] – time t2 / t5 between first and second pulse relay activation 1 / 2 [2 digits 00-99], where 00 means 0,5sec BRAVE – user guide...
Page 33
– turns on transmission serial code to activate the first switch. CAUTION - at activation this function never connect to the circuit electric lock without board COSW - code relay - threatens to destroy the relay in Brave communicator! The following codes may be the same or different for the resolution switching on multiple parallel connected relay code.
" *a " where a is just one number which activate the relay (star represents empty character and must be on first position). (Example at parametres 35,36) Parametr Value Description Default xxxx 0000 Service password (0000-9999) xxxx – service password to enter programming by phone (DTMF) BRAVE – user guide...
Page 35
– line hanging up by push of same button: k=0 feature is switch off k=1 again button push hang up the line CAUTION !! setting of this parametr has a big influence to numbers dialling BRAVE – user guide...
– when time between push of 2 following buttons is longer than time w then code is evaluated incorrectly. Number dial – when button which we push is first number in password for relay activation then dial is delayed about this time w BRAVE – user guide...
Page 37
– minimal number of busy tones neccessary for 625-725 675-775 detection [2-0], where 0 means 10 busy tones 725-825 z – minimal time of permanent tone duration (for dial tone detection on PBX) [1-5 sec] Parametr Value Description Default BRAVE – user guide...
Page 38
You can select rate 2,2 dB - p=0 (Europe) or rate 3,2dB - p=1 (Australia) s – listening –in DTMF level you can select in four levels: Level of listening in DTMF [dB] s - dial BRAVE – user guide...
The DIP switch 3 and 4 must be in position „on“ to activate this parametr w=1 . Deactivation - w=0. BRAVE – user guide...
Page 40
(1 or 2) in "electric lock" (modes 1 and 5). This feature is there because if you often use code lock function or exit button, so the switch-on time to hear the tone exchange. For some customers, this can be distracting. BRAVE – user guide...
Page 41
„failure“ mode“ then you have to use external power supply – put DIP switch 3 and 4 to position "on" – possible at version /C (C) only. It is the same like using Best Box option. BRAVE – user guide...
(noicy streets, subway stations, parkings…) then by activation of this circuit n=1 is setup level of noice as start level for microphone activation. Then the call connection is not one way opened. It relates with setup of parametres 71, 76, 77. BRAVE – user guide...
Page 43
Almost every country around the world has different telephone directives and this parametr allows decrease voltage at door intercom line interface about 1V during OFF HOOK. Where directive requires decreasement of line voltage I=0 decrease voltage about 1V. In default l=1. BRAVE – user guide...
Page 44
(0/1/2) Door intercom Brave includes circuit which during long distance installations (100m and more from PBX) can compensate losses on wiring. In default the feature is off k=0. You can setup in two levels depending on line current of PBX...
(0/1/#) When door intercom Brave includes RTC circuit - (C) version then you can activate automatical switching from real time a=1. The condition is correct time settings. You can verify it easily by diallingu a=# and door intercom reply either by confirmation tone (all is correct) or error tone (you have to setup the time).
Page 46
Then for setting after midnight you insert time 00:00. Setting sequence: 0406451505 and ♫, 0515000000 and ♫, 0600001200 and ♫ BRAVE – user guide...
"Default". CAUTION !!! the erasing is unreturnable !!! it is neccessary programm again 5.9 Programming termination Parametr Value Description Default E N D of programming After 9 dial in programming tone the door intercom hangs up. BRAVE – user guide...
0000 (0000-1111) activation code 2 pulses from phone abcd 0000 (0000-1111) activation code from other modes of switch abcd 0000 (0000-1111) Dial type v – tone / pulse (0/1) Character for call prolongation (* / #) BRAVE – user guide...
Page 49
Acoustic signalling (confirmation,error, empty (0/1) memory, call termination...) Acustic signalling OFF HOOK /ON HOOK (0/1) Acoustic signalling of beeping into call (0/1) External powering from power supply 12V (DIP 3,4) (0/1) Acoustic signalling of relay activation (0/1) BRAVE – user guide...
Page 50
- time setting hours hh and hhnnkkjj minutes nn starts day and hours kk and 00000000 minutes jj starts night thursday - time setting hours hh and hhnnkkjj minutes nn starts day and hours kk and 00000000 minutes jj starts night BRAVE – user guide...
Page 51
Default setting for parametres 4x only Default setting for parametres 5x only 5 only.. 6 only.. Default setting for parametres 6x only 7 only.. Default setting for parametres 7x only 0 only.. Default setting for parametres 0x only BRAVE – user guide...
Camera Parametres on page 18 ) - possible setting by progam 6.2 Mechanical dimensions Model dimension HxWxD [mm] Brave Smyle (1 and 2 185 x 99 x 40 buttons) Weather hood 68 x 103 x 60 Brave with weather hood...
10 Number under button Night/2gr 11 Number under button Night/2gr 12 Number under button Night/2gr relay 1 works in mode m=1 - 8 relay 2 works in mode m=1 - 8 Password for relay 1 3211 Day+Night (1 pulse) BRAVE – user guide...
Page 54
(1 pulse) 3422 password relay 2 Night (1 pulse) Night 3423 password relay 2 (1 pulse) Night 3424 password relay 2 (1 pulse) Night 3425 password relay 2 (1 pulse) 342* Night password relay 2 (2 pulses) BRAVE – user guide...
Page 55
0000-1111 0 / 1 Dial type tone / pulse * / # Call prolongation character Brave hanging up by phone Brave hanging up by phone Service password Code to switch into DAY Code to switch into NIGHT...