Advertisement

Quick Links

Brave – Door Intercom
Brave Smyle - C
Brave Smyle - LC
Brave Smyle - C/C
User guide
Version 2.6

Advertisement

Table of Contents
loading

Summary of Contents for Brave Smyle - C

  • Page 1 Brave – Door Intercom Brave Smyle - C Brave Smyle - LC Brave Smyle - C/C User guide Version 2.6...
  • Page 3 Dear customer Congratulation to your purchase of “BRAVE SMYLE door intercom”. The BRAVE Smyle door intercom is designed as universal project to be suitable for different installation on the field and brings more features and possibilities. This manual is designed for Urmet 1129 panel in 4 models with 1 or 2...
  • Page 4: Table Of Contents

    .................... 9 CHEMATICS INSTALLATION ....................12 ..................... 12 SSEMBLY 2.1.1 Assembly of Brave Smyle front panel ............12 2.1.2 Assembly of cards backlighting..............13 2.1.3 Wall mounting of Brave Smyle ..............13 2.1.4 Replacing of cards backlighting after wall mounting ....... 14 2.1.5...
  • Page 5 IME PROGRAMM AUTOMATIC SWITCHING ..............47 EFAULT SETTTING AND ERASING ............... 47 ROGRAMMING TERMINATION 5.10 ................48 ARAMETRES OVERVIEW TECHNICAL PARAMETRES ................52 ................52 LEKTRICAL PARAMETRES ................52 ECHANICAL DIMENSIONS TABLE FOR EASY PROGRAMMING ............53 BRAVE – user guide...
  • Page 6: Basic Description

     Programming by phone DTMF or by USB cable from PC  Integrated heating for PCB  Permanent cards lighting, switchable  Ground output for better protection against static electricity (C) – comfort model only (Comfort) /C - model with camera only BRAVE – user guide...
  • Page 7: Terminology

    PBX extension) The manufacturer continuously improves the product firmware. The technology used allows you to upload to Brave the latest version of the firmware any time using a standard computer with BraveSet and USB cable. The latest version of the firmware is available at http://www.alphatech.cz...
  • Page 8: Different Models Of Smyle Brave Door Intercom

    1.3 Different Models of Smyle Brave door intercom Brave door intercoms is designed as new generation of door intercom units reflects all experiences collected during last 10 years of succesfull sales of door enry solutions. Features and parametres are different for different models of intercom to provide best balance between price and usage value.
  • Page 9: Pcb Schematics

    All functional and connectional elements are marked by red rounded number at bellow picture. Explanation follow on next page. Pict. 1 Brave Smyle mother board (1) + (3) + (7) + (11) - version /C only relay 2 version (C) only...
  • Page 10 The power supply might be AC as same as DC, not depends on polarity, max consumption 250mA from 12V. The power supply might be used also for electrical lock powering. Then we recommend power supply 12V/1A. BRAVE – user guide...
  • Page 11 RFID, etc.. The heating has control element to restrict power. The remaining components are designed for voltage up 24V DC!!! It not depends on polarity. BRAVE – user guide...
  • Page 12: Installation

    2 Installation 2.1 Assembly 2.1.1 Assembly of Brave Smyle front panel BRAVE – user guide...
  • Page 13: Assembly Of Cards Backlighting

    2.1.2 Assembly of cards backlighting 2.1.3 Wall mounting of Brave Smyle Make the mounting by attached pack with screws and plug (drill 5mm). BRAVE – user guide...
  • Page 14: Replacing Of Cards Backlighting After Wall Mounting

    2.1.4 Replacing of cards backlighting after wall mounting 2.1.5 Cards exchange (name cards) Every button has own card ( label) holded by plastic flag ( via picture). You can print out paper labels from special Excel file (downloadable on www.alphatech.cz or ). BRAVE – user guide...
  • Page 15: Connection

    The basic functionality of intercom (voice communication) needs connection of telephone line only - LINE (8) on .Pict. 1 Brave Smyle. The line is connected by 2 wires (a,b) and in stand by has usually voltage 24V - 60V, short circuit current 20mA - 60mA. When line is OFF HOOK the line voltage is 7V - 10V.
  • Page 16: Code Relay (Cosw)

    2 m=5 - version (C) only. 2. Two power supply – possibility to use independently two power supply One for Brave Smyle and second for electrical locks. Second electrical lock is connected inversaly (fire emergency exit). 3. Combination of doors with electrical lock and sliding gate at fencing.
  • Page 17 Pict. 2 Examples of relay connection BRAVE – user guide...
  • Page 18: Camera ( /Cversion Only )

    - picture area: 5,78x4,19mm - resolution: 628x582pixel 380 rows - video output: 1V p-p/75 ohm - automatic profit control: 18dB - minimal lighting: 3LUX - automatic lens shutter: 1/60-1/15000sekund - camera view: 50st. - zoom: manually BRAVE – user guide...
  • Page 19: Accssesories

    You just registrate intercom as handset to DECT base station. All features of intercom are kept. Important: DECT base station must support DTMF transmission between each handsets (relay activation feature). BRAVE – user guide...
  • Page 20: Power Supply 12V

    2.4.4 Power supply 12V As standard we provide for Brave Smyle intercom AC power supply 12V/1A . It is not part of unit packaging. It must be ordered individualy. More info about electrical locks and power supply on www.alphatech.cz. 2.4.5 Programming cable USB USB cable is not part of packaging.
  • Page 21: Door Intercom Service

    3 Door intercom service Functionality of Brave Smyle door inercom is adjustable by parametres settings (via. Programming parametres capture page 26). 3.1 Signalling overview The Brave Smyle door intercom signalling acoustically stages which are happening during operation. Samples of acoustical sounds you can play in BraveSet ( PC programm).
  • Page 22: Visitor At The Door

    When call duration is longer then setup limit (parametr 52) the 10sec before hang up Brave intercom sends alerting tone of call ending. Mr. Scott can dial * or # up setting (parametr 42) to prolong the call about the time setup by parametr 52.
  • Page 23 332* According settings DAY/NIGHT 342* Internal code from phone You can dial 1 or 2 numbers of code 2digits code is default You can shorter it by using * on first digit of code during programming BRAVE – user guide...
  • Page 24: Person Inside Building

    Tab. 1 Table of relay(s) control 3.3 Person inside building By person inside building we mean person in telephone connection with Brave intercom , for example Mr. Scott. 3.3.1 Outgoing call Outgoing call is a call from door intercom (generated by visitor). After door intercom dial is ringing a phone inside the building.
  • Page 25: Incoming Call

    We choose when the direction to the phone is interrupted. If parameter 73 greater than parameter 72, thus favored direction to the speaker. We choose this if the interrupted sound in the speaker of communicator. BRAVE – user guide...
  • Page 26: Parametres Programming

    When you enter programming mode and do not make any dialling for 30seconds the door intercom will hang up. After each dialled DTMF tone the time is prolonged about 30seconds. You can finish programming mode also by dialling parametr 9. BRAVE – user guide...
  • Page 27: Pc Programming - Braveset Programm

    Details about setting you will find in programm HELP and on website www.alphatech.cz. USB cable is special cable with galvanical isolation and with 3V convertor. The galvanical isolation is neccessary because telephone line must not be grounded and PC´s are usually grounded. BRAVE – user guide...
  • Page 28: Descriprion Of Programmable Parametres

    (C) this mode switch up current time (when this feature is activated - parametr 084) Note: at version Brave Smyle - C and Brave Smyle - LC are available max. 2 buttons - tt=01-02 BRAVE – user guide...
  • Page 29: Relay(S)

    (setup in parametr 31r*). Due this you can select one button for every relay its pushing activate appropriate relay for time t1/t4. This mode serves as substitution of ring bell connected to Brave system. BRAVE – user guide...
  • Page 30 DAY. You have to keep certain rules for password dialling:  First button of password select from at least used button for direct dialling (-prolong dial time) BRAVE – user guide...
  • Page 31 (star represents empty character and must be on first digit position). Activation relay 2 pulses is suitable for example: at sliding gate which this way can also substitute wicket for person entrance. BRAVE – user guide...
  • Page 32 2 pulses relay r - time t2/t5 105 205 (00-99) – relay number [1-2] – time t2 / t5 between first and second pulse relay activation 1 / 2 [2 digits 00-99], where 00 means 0,5sec BRAVE – user guide...
  • Page 33 – turns on transmission serial code to activate the first switch. CAUTION - at activation this function never connect to the circuit electric lock without board COSW - code relay - threatens to destroy the relay in Brave communicator! The following codes may be the same or different for the resolution switching on multiple parallel connected relay code.
  • Page 34: Basic Parametres

    " *a " where a is just one number which activate the relay (star represents empty character and must be on first position). (Example at parametres 35,36) Parametr Value Description Default xxxx 0000 Service password (0000-9999) xxxx – service password to enter programming by phone (DTMF) BRAVE – user guide...
  • Page 35 – line hanging up by push of same button: k=0 feature is switch off k=1 again button push hang up the line CAUTION !! setting of this parametr has a big influence to numbers dialling BRAVE – user guide...
  • Page 36: Time Parametres

    – when time between push of 2 following buttons is longer than time w then code is evaluated incorrectly. Number dial – when button which we push is first number in password for relay activation then dial is delayed about this time w BRAVE – user guide...
  • Page 37 – minimal number of busy tones neccessary for 625-725 675-775 detection [2-0], where 0 means 10 busy tones 725-825 z – minimal time of permanent tone duration (for dial tone detection on PBX) [1-5 sec] Parametr Value Description Default BRAVE – user guide...
  • Page 38 You can select rate 2,2 dB - p=0 (Europe) or rate 3,2dB - p=1 (Australia) s – listening –in DTMF level you can select in four levels: Level of listening in DTMF [dB] s - dial BRAVE – user guide...
  • Page 39: System Parametres

    The DIP switch 3 and 4 must be in position „on“ to activate this parametr w=1 . Deactivation - w=0. BRAVE – user guide...
  • Page 40 (1 or 2) in "electric lock" (modes 1 and 5). This feature is there because if you often use code lock function or exit button, so the switch-on time to hear the tone exchange. For some customers, this can be distracting. BRAVE – user guide...
  • Page 41 „failure“ mode“ then you have to use external power supply – put DIP switch 3 and 4 to position "on" – possible at version /C (C) only. It is the same like using Best Box option. BRAVE – user guide...
  • Page 42: Handsfree Parametres Setting

    (noicy streets, subway stations, parkings…) then by activation of this circuit n=1 is setup level of noice as start level for microphone activation. Then the call connection is not one way opened. It relates with setup of parametres 71, 76, 77. BRAVE – user guide...
  • Page 43 Almost every country around the world has different telephone directives and this parametr allows decrease voltage at door intercom line interface about 1V during OFF HOOK. Where directive requires decreasement of line voltage I=0 decrease voltage about 1V. In default l=1. BRAVE – user guide...
  • Page 44 (0/1/2) Door intercom Brave includes circuit which during long distance installations (100m and more from PBX) can compensate losses on wiring. In default the feature is off k=0. You can setup in two levels depending on line current of PBX...
  • Page 45: Time Programm - Automatic Day/Night Switching (C)

    (0/1/#) When door intercom Brave includes RTC circuit - (C) version then you can activate automatical switching from real time a=1. The condition is correct time settings. You can verify it easily by diallingu a=# and door intercom reply either by confirmation tone (all is correct) or error tone (you have to setup the time).
  • Page 46 Then for setting after midnight you insert time 00:00. Setting sequence: 0406451505 and ♫, 0515000000 and ♫, 0600001200 and ♫ BRAVE – user guide...
  • Page 47: Default Settting And Erasing

    "Default". CAUTION !!! the erasing is unreturnable !!! it is neccessary programm again 5.9 Programming termination Parametr Value Description Default E N D of programming After 9 dial in programming tone the door intercom hangs up. BRAVE – user guide...
  • Page 48: Parametres Overview

    0000 (0000-1111) activation code 2 pulses from phone abcd 0000 (0000-1111) activation code from other modes of switch abcd 0000 (0000-1111) Dial type v – tone / pulse (0/1) Character for call prolongation (* / #) BRAVE – user guide...
  • Page 49 Acoustic signalling (confirmation,error, empty (0/1) memory, call termination...) Acustic signalling OFF HOOK /ON HOOK (0/1) Acoustic signalling of beeping into call (0/1) External powering from power supply 12V (DIP 3,4) (0/1) Acoustic signalling of relay activation (0/1) BRAVE – user guide...
  • Page 50 - time setting hours hh and hhnnkkjj minutes nn starts day and hours kk and 00000000 minutes jj starts night thursday - time setting hours hh and hhnnkkjj minutes nn starts day and hours kk and 00000000 minutes jj starts night BRAVE – user guide...
  • Page 51 Default setting for parametres 4x only Default setting for parametres 5x only 5 only.. 6 only.. Default setting for parametres 6x only 7 only.. Default setting for parametres 7x only 0 only.. Default setting for parametres 0x only BRAVE – user guide...
  • Page 52: Technical Parametres

    Camera Parametres on page 18 ) - possible setting by progam 6.2 Mechanical dimensions Model dimension HxWxD [mm] Brave Smyle (1 and 2 185 x 99 x 40 buttons) Weather hood 68 x 103 x 60 Brave with weather hood...
  • Page 53: Table For Easy Programming

    10 Number under button Night/2gr 11 Number under button Night/2gr 12 Number under button Night/2gr relay 1 works in mode m=1 - 8 relay 2 works in mode m=1 - 8 Password for relay 1 3211 Day+Night (1 pulse) BRAVE – user guide...
  • Page 54 (1 pulse) 3422 password relay 2 Night (1 pulse) Night 3423 password relay 2 (1 pulse) Night 3424 password relay 2 (1 pulse) Night 3425 password relay 2 (1 pulse) 342* Night password relay 2 (2 pulses) BRAVE – user guide...
  • Page 55 0000-1111 0 / 1 Dial type tone / pulse * / # Call prolongation character Brave hanging up by phone Brave hanging up by phone Service password Code to switch into DAY Code to switch into NIGHT...
  • Page 56 Fast switching voice 1 - 4 automatic 0 / 1 VA charakteristic Compemsation of wires 0 / 1 / 2 losses Signalling transmission 04 - 16 -dBm level 0 / 1 / # on/off. automatic switching BRAVE – user guide...
  • Page 57 Time setting Date setting+weekday w ddmmyyw sunday hhnnkkjj hhnnkkjj Monday hhnnkkjj Tuesday hhnnkkjj Wednesday hhnnkkjj thursday hhnnkkjj friday hhnnkkjj saturday BRAVE – user guide...
  • Page 58 Producer: Distributor: Sales date: © JR 2011-13 verze 2.6 X/13...

This manual is also suitable for:

Smyle - c/cSmyle - lc

Table of Contents