Caution on numbers identity of password. When one password includes
other, for example:password for relay1 is 1234 and for relay 2 12345,
then always after pushing button 4 relay 1 will be activated and relay 2
wont be never acivated. When you select password for relay 2 234,
then after button 4 pushing both relays will be activated.
Note1. switching to DAY/NIGHT mode stays setup in door intercom even after power
(line) disconnection. At version (C), when is activated, then DAY/NIGHT switching is
done up time and week table.
when you insert parametres
Note2.
you cant select them from button panel. Number 0 represents button 10.
Parametr
Value
35
r aa
– relay number [1-2]
r
aa – command (internal code) from phone for relay activation [2 digits] /
For both relays you can setup the same command (internal code) then both
relays are activated simultaneously. It is profitable to setup the same command
for relay activation as same as door intercom hang up (parametr 43) aa=bb.
– command has always 2 digits but when you want control relay by 1 digit
1
/
only ( from keypad of phone) then you have possibility to programm " *a " where
a is one number only which activate the relay (star represents empty character
and must be on first digit position).
Example: 1 relay activated by internal code 48 - dial 35148 ♫
2 relay activated by internal code 8 - dial 352*8 ♫
By dialling on phone 8 you activate relay 2 by dialling 48 you activate both relays
Parametr
Value
36
r cc
– relay number [1-2]
r
cc – command (internal code) from phone for relay activation [2 digits] /
For both relays you can setup the same command (internal code) then both
relays are activated simultaneously.
– command has always 2 digits but when you want control relay by 1 digit
1
/
only ( from keypad of phone) then you have possibility to programm " *a " where
a is one number only which activate the relay (star represents empty character
and must be on first digit position).
Activation relay 2 pulses is suitable for example: at sliding gate which this way
can also substitute wicket for person entrance.
BRAVE – user guide
32,33,34 do not use character # and * because
Description
command aa from phone for relay activating
r 1 pulse
Description
command aa from phone for relay activation
r 2 pulses
Default
155 266
(00-99,*0-*9)
Default
150 260
(00-99,*0-*9)
1
1