3.2 Visitor at the door

Door intercom buttons have signs (cards) like usual ring buttons. Visitor
find desired name (for example"Scott") and push it. The Brave intercom pick up
the line and "play" tone line pick up (when is not switch off by par.62) and dial
phone number saved under the button (parametr 1 or 2 up door intercom mode).
From Brave intercom speaker you hear ringing tone and phone of Mr. Scott is
ringing. As soon as Mr. Scott pick up ringing phone he can talk to visitor at the
door. When is electrical lock connected to Brave intercom then Mr. Scott can
open the door for visitor by dial DTMF code on his phone. When Mr. Scott hang
up the phone then Brave intercom hangs up as well after busy tone detection.
When call duration is longer then setup limit (parametr 52) the 10sec before
hang up Brave intercom sends alerting tone of call ending. Mr. Scott can dial *
or # up setting (parametr 42) to prolong the call about the time setup by
parametr 52.
Dialled number from Brave intercom is different up dial mode setup in the
unit by (parametr 47):
- Day/Night mode = when intercom is in DAY mode then number setup by
parametru 1 is dialled. When intercom is in NIGHT mode then always dial
number setup by parametr 2. Manual intercom modes switching is setup
by parametres 45,46. In version (C) you can switch DAY/NIGHT mode
automatically. Selection of dialled number saved under the button is control
by time up table (parametry 00-06).
- 2 groups numbers mode = first button push – always dial number setup
by parametr 1. When the same button is pushed or 10seconds after dial
busy tone is detected, or setup number of rings is out (parametr 56) the
door intercom dial number from second group setup by (parametr 2). When
you push the same button again you will dial again number from first group
etc.......(when after dial number from second group busy tone is detected
the repeating is finished)
When visitor push the button after line is picked up the door intercom
hangs up for time setup by parametr 54 and then picks up the line and dial new
number ( second push number). The number dialling is either by tone dial
(DTMF) or pulse dial up setting by parametr 41. There is one more option and it
is line hangs up by again pushing of same button (parametr 4*).
You can control relay(s) by door intercom buttons (code lock). When
visitor push buttons in order which match to setup code (parametr 32-34) and
time between each button press is not longer than setup by (parametr 53) then
door intercom picks up and activate appropriate relay (when relay setup is mode
m=1 or m=5) for time setup by parametr 37 eventually.39,30. Then hangs up.
The relay (up control code) can activate one pulse or two pulses with time
between each pulse setup by parametr 30 via. Tab. 1.