Brave Smyle - C User Manual page 33

Door intercom
Table of Contents

Advertisement

Parametr
Value
3#0
– turns on transmission serial code to activate the first switch.
p
CAUTION - at activation this function never connect to the circuit electric lock
without board COSW - code relay - threatens to destroy the relay in Brave
communicator!
The following codes may be the same or different for the resolution switching on
multiple parallel connected relay code.
Parametr
Value
3#1
abcd
abcd –
Brave sends a serial code for the code relay (COSW) after
evaluation code from keys (keyboard) namely for 1 pulse
Parametr
Value
3#2
abcd
abcd –
Brave sends a serial code for the code relay (COSW) after
evaluation code from telephone (DTMF) namely for 1 pulse
Parametr
Value
3#3
abcd
abcd –
Brave sends a serial code for the code relay (COSW) after
evaluation code from keys (keyboard) namely for 2 pulses
Parametr
Value
3#4
abcd
abcd –
Brave sends a serial code for the code relay (COSW) after
evaluation code from telephone (DTMF) namely for 2 pulses
Parametr
Value
3#5
abcd
abcd –
Brave sends a serial code for the code relay (COSW) after
evaluation code from other modes m switch 1
BRAVE – user guide
Description
p = 1 enabled / disabled p = 0 connection
p
code relay COSW
Description
activation code 1 pulse from buttons
Description
activation code 1 pulse from phone
Description
activation code 2 pulses from buttons
Description
activation code 2 pulses from phone
Description
activation code from other modes of switch
Default
(0/1)
Default
(0000-1111)
Default
(0000-1111)
Default
(0000-1111)
Default
(0000-1111)
Default
(0000-1111)
0
0000
0000
0000
0000
0000
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smyle - c/cSmyle - lc

Table of Contents