Summary of Pushbutton Programming Commands
Name
Command
Add/Modify
100 #
Users
NNN #
UUUU {UUUU}#
UUUU {UUUU}#
101 #
NNN #
UUUU {UUUU}#
UUUU {UUUU}#
102 #
NNN #
UUUU {UUUU}#
UUUU {UUUU}#
HH#
103 #
UUUU {UUUU}#
UUUU {UUUU}#
Delete Users
200 #
NNN#
201 #
NNN#
202 #
NNN#
299 #
32
Description of Command
'Add/Modify User Access Code' NNN = spe-
cific User ID location (001 to 299)
(Combination length can be 4 to 8 digits,
depending on access length LL setting)
'Add/Modify Manager Access Code' NNN =
specific User ID location (001 to 299)
(Combination length can be 4 to 8 digits,
depending on access length LL setting)
'Add/Modify Service User Access Code' NNN
= specific User ID location (001 to 299) (HH
= 01 to 24 hours - duration time in hours; 00
= one-time entry; Combination length can be
4 to 8 digits, depending on access length LL
setting)
'Modify M-Unit User Code' (Combination
length can be 4 to 8 digits, depending on
access length LL setting)
'Delete User Access Code'
'Delete Manager Access Code'
'Delete Service User Access Code'
'Delete all User Access Codes' (except
Master, Manager and M-Unit User)
Authorization
Master, Mgr
Master
Master, Mgr
Master, Mgr
Master, Mgr
Master
Master, Mgr
Master, Mgr

Advertisement