Approved Vent Configurations; Maximum Vent Run And Rise - DaVinci Category 1 Owner's Manual

Gas-fired domestic and commercial heating equipment “vented gas fireplace”
Table of Contents

Advertisement

42

Approved Vent Configurations

Maximum Vent Run and Rise

The fireplace vent must meet the following requirements (measured from base of fireplace):
Minimum Vent Length 3' (1 M)
Maximum Horizontal Run = 33' (11 M)*
Maximum Vertical Rise = 40' (13 M)*
Maximum Vertical Drop = 6' (2 M)*
Maximum 90˚ Elbows = 4 (note: two 45˚ elbows count as one 90˚ elbow)
* For installations exceeding this limit, contact Travis Industries for further review and approval.