Hearth Requirements; Facing Requirements - DaVinci Category 1 Owner's Manual

Gas-fired domestic and commercial heating equipment “vented gas fireplace”
Table of Contents

Advertisement

48

Hearth Requirements

A hearth is not required for this fireplace. If a hearth is installed, it must not extend above the glass
opening (we recommend the hearth be a minimum 1" below the glass opening to allow for glass
installation). The hearth may be combustible or non-combustible.

Facing Requirements

Drywall, tile, or other facing (combustible or non-combustible) may be placed directly on the face of
the fireplace (see "a" below).
Facing may be placed along the perimeter of glass opening, but must not extend over it. This area
must remain open to allow for glass removal and installation.
Fireplace must not be used to support the facing. Heavy facing must be self-supporting.
WARNING: Do not use adhesive to secure the facing. The high temperatures of the
fireplace may cause adhesives to emit odors. Use mastic or thin set (or other non-
combustible, non-odorous adherent) to attach the facing.
NOTE: Screws may be used to secure cement board or tile backer to the fireplace. Do not
penetrate the fireplace more than 1/2" (13mm).
© Travis Industries
Installation
12" (305mm)
------- or -------
20" (508mm)
11"
280mm
(for qualified installers only)
See "Dimensions"
Do not drill screws into this shaded area.
The outer glass slides into this area.
4140805
100-01384