Approved Vent Configurations

The fireplace vent must meet the following requirements (measured from base of fireplace):
Minimum Vent Length = 3' (1 M) - Interior blower requires a minimum 5' (1.6 M) vent length
Maximum Horizontal Run = 100' (30 M)*
NOTE: Vent does not require any vertical rise along its run.
Maximum Vertical Rise = 100' (30 M)* (measured from base of fireplace)
Maximum Vertical Drop Below Base of Fireplace = 6' (2 M)*
NOTE: The downward vent sections may not exceed 10' total.
Maximum 90˚ Elbows = 4 (note: two 45˚ elbows count as one 90˚ elbow)
Use the table below to determine which blower must be used.
* If you wish to place the termination outside the shaded regions, or if additional elbows are
required, you must contact Travis Industries to verify vent configuration.
100 feet (30m)
80 feet (24m)
60 feet (18m)
40 feet (12m)
20 feet (6m)
-6 feet (-2m)
Compatible Exhaust Blower
Category 1
© Travis Industries
Installation
0 feet
(for qualified installers only)
36 x 36
RS12 or Inline 160
9/25/17-1468
36 x 58
RS16 or Inline 180
Maestro