Vent Requirements; Vent Clearances; Altitude Considerations; Approved Vent - DaVinci Category 1 Owner's Manual

Gas-fired domestic and commercial heating equipment “vented gas fireplace”
Table of Contents

Advertisement

Vent Requirements

The gas appliance and vent system must be vented directly to the outside of the building, and never
be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent
gas appliance must use its own separate vent system.
In addition to the requirements listed here, follow the requirements provided with the vent.
A firestop is required whenever the vent penetrates a wall, floor, or ceiling (passes through framing
members). Firestops may be provided by the vent manufacturer (1" clearance).

Vent Clearances

The vent must maintain the required clearance to combustible materials to prevent a fire. Do not fill
air spaces with insulation.
Minimum Clearance to Vent

Altitude Considerations

This fireplace has been tested at altitudes ranging from sea level to 6,000 feet (1800 M). In this testing we have
found that the fireplace, with its standard orifice, burns correctly with just an air shutter adjustment.
Failure to adjust the air shutter properly may lead to improper combustion which can create a safety hazard.
Consult your dealer or installer if you suspect an improperly adjusted air shutter.

Approved Vent

Use listed 10" B-Vent (typically 11" 279mm outer diameter). This vent is available from Travis
Industries.

Vent Installation

Before installing vent sections, place a bead of high-temperature silicone around the joint to ensure
an air-tight seal.
Lock the vent sections together and use screws to secure.
Horizontal sections require non-combustible support every three feet (e.g.: plumbing strap)
© Travis Industries
Installation
(for qualified installers only)
1" (25mm)
4140805
41
100-01384