Maintenance - Nimbus Water Systems Cascade Owner's Manual & Installation Manual

Drinking water filtration system
Table of Contents

Advertisement

ascade
C
Cartridge Replacement
1. Close the feed water shut-off valve.
2. Open the dispensing faucet.
3. Pull the manifold unit from the installed location.
4. Remove the retaining clip at the front of the unit by pulling back the slide lock and squeezing and pulling to remove.
Pull the cartridge off the manifold evenly at top and bottom. Dispose of used cartridge.
5. Install the new cartridge, rocking gently from side to side as necessary until the cartridge tubes are properly engaged in
the manifold connectors. Install the retaining clip ensuring the slide locks snap into place in the slots. If the clip does
not snap easily into place through the slots it means the cartridge is not fully inserted into the connectors. Press top or
bottom of cartridge to engage connectors until it snaps into place properly.
6. Close the dispensing faucet. Turn on feed water valve. Observe system for any leaks, especially at newly re placed car-
tridge.
7. If the replaced cartridge was a carbon filter, open the dispensing faucet and let water run for at least 3 minutes to flush
out any carbon fines.
10

Maintenance

42445 Avenida Alavardo, Temecula, CA 92590
(800) 451-9343, www.nimbuswater.com