    ascade DRINKING WATER FILTRATION SYSTEM Owner's Manual & Installation Guide 42445 Avenida Alvarado, Temecula, CA 92590 800-451-9343 www.nimbuswater.com 42445 Avenida Alavardo, Temecula, CA 92590 (800) 451-9343, www.nimbuswater.com...
  • Page 2 Please fill out this form immediately after installation and retain for future reference. Model Number NS-14-__ __ Code __ __ __ __ __ (On right side of frame below model number) Install Date Service Phone 42445 Avenida Alavardo, Temecula, CA 92590 (800) 451-9343, www.nimbuswater.com...
  • Page 3 Introduction to the Cascade Drinking Water System Congratulations on your purchase of the Cascade Drinking Water System. When properly maintained, this system will pro- vide you with years of trouble-free service. The next three sections contain important information on the proper care and maintenance of your system, please take a few minutes to read through this information.
  • Page 4: Warranty

    ascade Warranty This Limited Warranty extends to the original purchaser of the system only. This warranty covers all Manufacturer-supplied items only that prove to be defective in material, workmanship or factory preparation. This warranty covers parts only; all labor is excluded from this war- ranty, including, but not limited to, services related to the removal, replacement, installation, adjustment, maintenance and/or repair of the unit or its components items.
  • Page 5: Typical Installation Diagram

    Improperly installed systems could result in water damage due to leaks or flooding. BACK COVER The connection parts kit supplied with the Cascade Drinking Water Filtration System includes components which repre sent the most common under-sink plumbing connections currently in use within the United States. If these components do not match the type of connections installed at your location, contact a local hardware or plumbing supplier to obtain the correct fittings.
  • Page 6 ascade Feed Connection 1. Locate and turn off the angle stop valve on the cold water line feeding the sink. This valve will usually be located under the sink on the pipe coming out of the wall. 2. When the angle stop valve is closed, relieve pressure in the line by opening the cold water tap on the sink.
  • Page 7: Faucet Installation

    Faucet Installation Determine the most practical under-the-sink location for placement of the Cascade system. Ensure that the location allows adequate access for cartridge re placement. The faucet installation instructions below are for a standard non-airgap faucet with a quick-connection fitting. Your faucet installation may vary.
  • Page 8: Manifold Installation

    Manifold Installation Determine the most practical under-the-sink location for placement of the Cascade manifold unit. Ensure that the specific location allows adequate access to the manifold unit for cartridge re placement. 1. Place the manifold in the selected location. If desired, the #6 self tapping screws may be used to secure the manifold unit in position by means of the top rear and bottom lip mounting holes.
  • Page 9 Checklist 1. Cascade unit is located where it will not be subject to physical impacts or rough contact by heavy objects. 2. Feed water pressure to the unit is no less than 40 psi and no greater than 100 PSI.
  • Page 10: Maintenance

    ascade Maintenance Cartridge Replacement 1. Close the feed water shut-off valve. 2. Open the dispensing faucet. 3. Pull the manifold unit from the installed location. 4. Remove the retaining clip at the front of the unit by pulling back the slide lock and squeezing and pulling to remove. Pull the cartridge off the manifold evenly at top and bottom.