Desalinator Replacement
1.
Close the feed water shut-off valve and close the tank shut-off valve.
2.
Open the dispensing faucet to relieve system pressure. Close dis-
pensing faucet when fl ow has stopped.
3.
Remove old desalinator from clips on frame. Install new desalinator
on frame.
4.
Remove feed tube from old desalinator and insert it in the (green)
feed connector of the new desalinator. See Figure 6.
5.
Repeat tube removal and replacement steps for product and drain
tubes.
6.
Turn on feed water shut-off valve and open dispensing faucet.
7.
Close dispensing faucet aft er water starts running.
8.
Observe system for any leaks, especially at newly re placed cartridge.
9. Open the tank shut-off valve.
10. The system should be fl ushed at least once as described above under
Secti on 8.
Filter Replacement
1.
Close the feed water shut-off valve and close the tank shut-off valve.
2.
Open the dispensing faucet to relieve system pressure. Close dis-
pensing faucet when fl ow has stopped.
3.
Remove the prefi lter housing by turning it clockwise (when viewed
from above). Remove old prefi lter from housing and discard. Remove
O-ring from top of housing. Wash O-ring and housing. Replace O-ring in
groove at top of housing. Insert new fi lter. Replace housing into cap by
turning counter clockwise. (When viewed from above).
4.
Repeat Step 5 for postf ilter.
5.
Turn on the feed water valve and open the tank shut-off valve.
6.
Observe system for any leaks, especially at newly re placed cartridge.
7.
The system should be fl ushed at least once as described in System
Acti vati on and Flushing.
CS-2 Maintenance
42445 Avenida Alvarado, Temecula, CA 92590
(800) 451-9343, www.nimbuswater.com
To Drain
(Yellow Collet)
Product
(Blue Collet)
Feed
(Green Collet)
Fig. 6